background image

One Stop Systems 

 

OSS-KIT-EXP-6002| 14 

 

 

 

 

5      Contacting Technical Support 

Our support department can be by phone at  

1 (760) 745-9883

. Support is available Monday through Friday, 8:00 AM to 5:00 PM PT. When 

contacting One Stop Systems Technical Support, please be sure to include the following information: 

1) Name 
2) Company Name 
3) Phone Number 
4) Fax Number 
5) Email Address 
6) Model Number 

7) Serial Number 
8) Computer Make 
9) Computer Model 
10) Operating System and Version 
11) Make/Model of PCI cards in expansion chassis 
12) Detailed description of the problem 

 

 

You can also visit our web site at:  

HT

www.onestopsystems/support/

T

 

For a quick response, use the Technical Support and RMA Request Form available in the Support Section of the website. Simply complete the 
form with all required information. Please make sure that your problem description is sufficiently detailed to help us understand your problem.  

For example: Don’t say “Won’t boot up.” Do say “Tried all the steps in the Troubleshooting Section and it still won’t boot up.” 

For faster diagnosis of your problem, please run the two utility programs described in the following sections and include the diagnostic files 
they generate with your email. 

 

6      Returning Merchandise to One Stop Systems 

If factory service is required,  you must contact OSS Service Representative to obtain a Return Merchandise Authorization (RMA) number. Put 
this number and your return address on the shipping label when you return the item(s) for service. 

One Stop Systems  will return any product

 

that is not accompanied by an RMA number

.  Please note that One Stop Systems WILL NOT accept COD packages, so be sure to return the 

product freight and duties-paid.  

Ship the well-packaged product to the address below: 

RMA # ________ 

One Stop Systems 

2235 Enterprise Street, Suite#110 92029 

USA 

It is not required, though highly recommended, that you keep the packaging from the original shipment of your One Stop Systems product.  
However, if you return a product to One Stop Systems for warranty repair/ replacement or take advantage of the 30-day money back 
guarantee, you will need to package the product in a manner similar to the manner in which it was received from our plant.  One Stop Systems 
cannot be responsible for any physical damage to the product or component pieces of the product (such as the host or expansion interfaces for 
the PCIe expansion chassis) that are damaged due to inadequate packing.  Physical damage sustained in such a situation will be repaired at the 
owner’s expense in accordance with Out of Warranty Procedures.  Please, protect your investment, a bit more padding in a good box will go a 
long way to insuring the device is returned to use in the same condition you shipped it in. Please call for an RMA number first. 

Summary of Contents for OSS-KIT-EXP-6002

Page 1: ...Host Server to Expansion System Kit User Manual OSS KIT EXP 6002 SKU OSS KIT EXP 6002 www onestopsystems com ...

Page 2: ...s 8 3 1 Installing the Adapter Kit 8 3 2 Expansion link board 8 3 3 Removing PCIe Cable 8 3 4 Operation 8 4 Technical Information 9 4 1 Signal Adjustment 9 4 2 Pin Assignments 9 4 3 Pin out for the PCIe x4 Card Edge Connector on the Host Cable Adapter 10 4 4 PCI Express x4 Connector PIN Assignment 11 4 5 Pin out for the PCIe x4 Cable 11 4 6 Signal Descriptions 12 4 7 Connector Pin outs for the PCI...

Page 3: ...nto a PCIe slot of the server It then cables to a downstream expansion link board ELB The ELB acts as a downstream cable link board and the primary fan out switch to support multiple configurations of PCI express expansion slots The host adapter installs into a PCIe x4 x8 or x16 slot on the host motherboard It then cables to the expansion link board and installs in the SHB or system slot of a CPCI...

Page 4: ...1 3 backplane Support half height bracket The Host and Target cable adapter cards require no software drivers 1 1 2 x4 Link Cable Available in 1m 2m 3m 5m 7m lengths PCI SIG Express Cable Specification Compliant Includes x4 PCIe lane and side band signals for o Power ON o Reset o PCIe clock o Cable Present o Wake Positive latching mechanism per PCI SIG specification Support 10 Gbps full duplex tra...

Page 5: ...Dimension H x L 3 937 x 6 299 in 100 x 160 mm 1 slot wide Switch PLX PEX8733 32 lane switch Upstream Interface x4 PCI Express over cable PCI SIG PCI Express Cable Rev 2 0 Compliant Downstream Interface 16 lanes of PCI Express on the backplane connectors The lanes form two or four links to the backplane through the XP2 and XP3 connectors per the PICMG EXP 0 specification The following link modes ar...

Page 6: ...h 1m 2m 3m 5m 7m Circuits loaded 38 Gender Male to Male Lock to Mating Part Yes Material Metal Zinc Alloy Pitch Mating Interface 0 80mm 0 31 Single Ended No Water proof Dust proof Yes Wire Insulator Diameter N A Wire Size AWG 28 Wire Cable Type Round Electrical Current 1A Max per contact Shielded Yes Voltage Maximum 30V DC ...

Page 7: ...st computer s PCIe x4 x8 or x16 slot Cable LED indicators are the same for both Host and Target configurations 2 2 Expansion Link Board The Expansion Link Board ELB OSS CPCIe3 3U 6U ELB x4 is a downstream link board that installs into a CPCIe chassis The ELB fits into the system slot of a CPCIe backplane The ELB is the downstream link board and the primary fan out switch to support multiple config...

Page 8: ...on link board 1 Insert the expansion link board into the SHB slot on the chosen backplane 2 Connect the x4 PCIe cable to both cables adapter cards Press or pull the green TAB while slowly inserting the cable then release it to lock the cable See photos below 3 Test by pulling back on the connector 3 3 Removing PCIe Cable 1 To remove the cable press or pull the green tab and slowly pull the cable o...

Page 9: ...ilable for this purpose It is highly recommended to contact OSS customer support before making changes to these settings Having the customer solder to the board should void the warranty 4 1 Signal Adjustment 4 2 Pin Assignments Host and Target card connectors x4 Card Edge Connector The pins are numbered as shown with side A on the top of the centerline on the solder side of the board and side B on...

Page 10: ...er differential pair Lane 0 17 PRSNT2 Hot Plug presence detect PERn0 18 GND Ground GND Ground 19 PETp1 Transmitter differential pair Lane 1 RSVD Reserved 20 PETn1 GND Ground 21 GND Ground PERp1 Receiver differential pair Lane 1 22 GND Ground PERn1 23 PETp2 Transmitter differential pair Lane 2 GND Ground 24 PETn2 GND Ground 25 GND Ground PERp2 Receiver differential pair Lane 2 26 GND Ground PERn2 2...

Page 11: ... A8 PETp2 Differential Pair PERp2 B8 A9 PETn2 PERn2 B9 A11 PETp3 Differential Pair PERp3 B11 A12 PETn3 PERn3 B12 A14 CREFCLK Differential Pair CREFCLK A14 A15 CREFCLK CREFCLK A15 A17 SB_RTN Hook up Wire SB_RTN A17 A18 CPRSNT Hook up Wire CPRSNT A18 A19 CPWRON Hook up Wire CPWRON A19 B2 PERp0 Differential Pair PETp0 A2 B3 PERn0 PETn0 A3 B5 PERp1 Differential Pair PETp1 A5 B6 PERn1 PETn1 A6 B8 PERp2...

Page 12: ...B3 PERn0 B4 GND Ground reference B5 PERp1 Differential PCI Express Receiver Lane 1 B6 PERn1 B7 GND Ground reference B8 PERp2 Differential PCI Express Receiver Lane 2 B9 PERn2 B10 GND Ground reference B11 PERp3 Differential PCI Express Receiver Lane 3 B12 PERn3 B13 GND Ground reference B14 PWR 3 3V Cable Power B15 PWR B16 PWR_RTN Cable Power Return PETp x PCI Express Transmit Positive signal of x p...

Page 13: ...N B18 CWAKE Power management signal for wakeup events optional B18 CPERST Cable Reset 4 8 PCI Express x4 Connector PIN Assignment CFG 0 2 BP PORT CFG 0 1 2 A0 A1 A2 A3 B0 0 0 0 X4 X4 X4 X4 X4 0 1 0 X8 0 X4 X4 X4 0 1 1 X8 0 X8 0 X4 1 X X X16 0 0 0 X4 ...

Page 14: ...t contact OSS Service Representative to obtain a Return Merchandise Authorization RMA number Put this number and your return address on the shipping label when you return the item s for service One Stop Systems will return any product that is not accompanied by an RMA number Please note that One Stop Systems WILL NOT accept COD packages so be sure to return the product freight and duties paid Ship...

Page 15: ...One Stop Systems OSS KIT EXP 6002 15 ...

Reviews: