12.8 Expansion System fails to turn ON
Issue:
The 4U Value expansion system is not powering ON after replacing the target and host cards.
Troubleshooting steps:
1.
Shutdown the system (computer and expansion unit).
2.
Disconnect the link cables.
3.
Remove the Target and Host cards. Check the target and host cards, make sure you have the correct model OSS-PCIe-HIB38-x16-F.
4.
Check the switch settings on the target card.
5.
Check the switch settings on the host card.
6.
Reinstall the target card (plug the card into target slot).
7.
Reinstall the host card (plug the card into x16 Gen3 slot).
8.
Make sure the target and host cards are fully seated in the slot and firmly secured.
9.
Reconnect the link cables. Make sure the cables are properly connected.
10.
Power UP the host computer and expansion system will turn ON.
11.
If the expansion system is still not turning ON do the following:
a. Move the host card to another PCIe slot (in the host computer). Make sure the slot is x16 Gen3.
b. Try another computer.
c. Try another link cable (if available).
d. Try another set of adapter cards.
e. Send the unit for service / repair. You may be having a faulty boards.