PRODUCT SETTINGS AND CONFIGURATION
34
OI-6000-X-X-X-X-O OPS_GUIDE_REV 3.1
3.11
MODBUS BAUD SETTING
The baud rate is the speed of data transmitted within the Modbus system, measured in bits per second (bps). For
successful communication, the baud rate setting of the OI-6000 MUST match the baud rate setting on the attached
Otis Monitor, or other Modbus device.
All Otis devices have factory default Modbus baud settings of 9600 bps.
The RS-485 Modbus communication
parameters used in all Otis devices are
8 data bits, no parity bit, and 1 stop bit (8-N-1)
these parameters are fixed
and cannot be changed.
Some devices come with different Modbus baud rates. Check with your system
administrator to determine if a different Modbus baud setting is needed for your system.
The pre-set Modbus baud setting available for the OI-6000 are the following:
110 bps
300 bps
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
1.
Use the ADD and SUB buttons to scroll through the available Modbus baud options.
2.
Press the MENU button to select the desired setting and to advance to the 4-20 mA offset settings screen.