8.3 Warning for older type of hinge PCB’s.
Some of the older type hinge PCB’s are not compatible to the type 87, and some of type 87 parts are
not backward-compatible to older types of lifts.
PCB’s which you can/ may use in combination with the 86900 PCB and transformer are;
-
Sliding hinge ssp 042 V6 (mounted in the cover of the hinge) (used since March 2007)
-
Folding hinge ssp 007 V3 (mounted under the rail)
(used since March 2008)
-
Folding hinge ssp 008 V3 (mounted in the chair)
(used since March 2008)
8.4 Sliding hinge uses too much current. (friction in application.)
To prevent melting of the 5A fuse , when the hinge-application gives too much friction, we added
electronics which measure the output current on x10 pin 3.
When the current consumption of the hinge becomes too high, the electronics will switch off the
power for approximately 1 sec.
This can be repeated 10 times. Then the PCB shows error 8-8-8-8-J and all output voltages will be
switched off.
You can reset this error by controlling the lift on the armrest for 1 second.