6
2. Functionality and connections
2.1 Controls
If one of these controls is activated, and the safety contacts are not operated, the chairlift will start to
move in the controlled direction.
Control input
connected
to
connector-name
Control armrest right
(NO)
X2a-
1,3
Arm1
Control armrest left
(NO)
X2a-
2,3
Arm1
2-channel receiver (Remote right)
(NO)
X8-
3,4
Remote
2-channel receiver (Remote up)
(NO)
X8-
5,6
Remote
2.2 Safety inputs
If one of these safety devices is controlled the lift can not be moved in any direction.
Control input
connected
to
connector-name
Armrest-switch
(NC)
X2b-
1,2
Arm 2
Swivelseat switch
(NC)
X2c-
1,2
Seat
1-channel receiver/hinge PCBssp 008/sensor
(NC)
X7-
3,4 & 5,6
Extra
Contact
Overspeed governor (catch)
(NC)
X9b-
1,2
Catch
2.3 Sensitive edges safety inputs
Sensitive edges safety inputs right side
If one of these safety devices are controlled, the lift can not move in the right direction.
It is still possible for the lift to move in the left direction.
Control input
connected
to
connector-name
Endswitch right
(NC)
X3a-
1,2
Endswitch
Safety drive unit right
(NC)
X4-
1,2
Drive
Safety footrest right
(NC)
X5-
1,2
Foot
Safety chairframe right
(NC)
X6-
1,2
Frame
Summary of Contents for 87
Page 1: ...Otolift type 87 Functionality troubleshooting Date 221209 ...
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ...Type 86 Type 87 ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......