7 degree reference.
Control the lift for 10 seconds (reset) Verify if lift
is running OK after resetting 10 seconds.
Tilt sensor should light continuesly when running
over straight railpart chair moves.
Control the lift 2 times for 15 seconds. Lift may
not move. Display mainboard will show E98,
Sensor control board will show E60.
Set mountingplate to 0 degrees (Neutral).
Tighten al screws.