background image

P  4

Maintenance Weekly Schedule  

Weekly Schedule 

1.  Inspect all equipment for damage, leaks, or build-up of paint. 

2.  When shutting down over two days or longer, either circulate the paint or flush system with 

solvent and leave solvent in the lines. 

3.  Always circulate and agitate metallic paints and any other materials that settle out rapidly. 

But avoid excessive agitation which introduced air into the paint stream, giving the appearance 

of leaking fluid valves 

4.  Suspend hoses and cables off the floor ( not from heated lines or cords ) and avoid kinks 

5.  Remove nozzle only when necessary for cleaning or replacement. 

6.  To aid in the removal of dried paint during clean-up, apply a light coat of petroleum jelly to the 

exterior surface of the gun. 

Thank you for the opportunity given to OTSON and trust that OTSON shall be your good partner !! 

For further technical supports:
Please contact local agent or OTSON.  

Summary of Contents for OTS-3000

Page 1: ...User Manual V 7 8 Model OTS 3000 Stardand Package Professional Package Golden Package Solvent base Waterborne...

Page 2: ...d TIN Nozzle P 12 13 Installation of Round FRP Nozzle P 14 15 Installation of Flat FRP Nozzle P 16 20 LIQUID ELECTROSTATIC POWER SUPPLY P 21 MANUAL LIQUID ELECTROSTATIC SPRAY GUN P 22 ASSEMBLY P 23 24...

Page 3: ...grounding is a matter of proper equipment maintenance Inspect all ground wires daily 2 Verify that Solvent Safety container is grounding 3 Before operation please check the electrostatic output Ref 30...

Page 4: ...xcessive agitation which introduced air into the paint stream giving the appearance of leaking fluid valves 4 Suspend hoses and cables off the floor not from heated lines or cords and avoid kinks 5 Re...

Page 5: ...le to offer tranfer efficiency up to 95 and minimize the over spraying phenomenon obviously OTS 3000 Manual Liquid Electrostatic Spray System OTS 3000 Manual Liquid Electrostatic Spray Gun contains th...

Page 6: ...ade of friction resistant tungsten copper for prolonging the service life 6 The gun is made of HV resistant material while the handle is made of low impedance compound The structure of the gun is long...

Page 7: ...zzle Round FRP Nozzle Flat FRP Nozzle Specification Out Voltage 0 70KV DC Out Current 50 microamperes Input Voltage 110 V 240 V AC 50 60 Hz Intercepting current 20 150 microamperes Weight 12 kg Dimens...

Page 8: ...ctive liquid electrostatic enclosing or cause damage to the liquid electrostatic power supply by the false potential inside the unit 2 The sprayed object should be kept in grounding status constantly...

Page 9: ...shoes the paint lumps attached to the shoe bottom shall also be removed 2 Disconnect the power of the HV generator before cleaning the nozzle Before cleaning the nozzle or when the spray operation is...

Page 10: ...e cleaned regularly If the residual paints are left in the spraying room and the exhaustion device then these residues may become flammable substances in case of fire 9 The air compressor shall be ful...

Page 11: ...Item Description Q ty Set OTS 3000 GTFL OTS 3000 Golden Package 1 Including Manual Electrostatic Spray Gun 1 Electrostatic Power Supply 1 Round Tin Nozzle 1 Round FRP Nozzle 1 FLAT FRP Nozzle 1 High V...

Page 12: ...P 12 1 2 3 4 Installation of Round TIN OTS 3000 User Manual Installation...

Page 13: ...rover Date Version Drawing OTS 3000 3000AL Round TIN Nozzle Parts List Table Figure 1 NUM Part Description Qty pcs 1 3000AL01 Air Front Cap TIN 1 2 3000AL02 Round Nozzle Body TIN 1 3 3000AL03 Air Cap...

Page 14: ...P 14 OTS 3000 User Manual Installation Installation of Round FRP Nozzle 1 2 3 The Spray Direction of High Atomized Nozzle...

Page 15: ...ner Checker Approver Date Version Drawing OTS 3000 2 3 4 1 3000AK Round FRP Nozzle Parts List Table Figure 1 NUM Part Description Qty pcs 1 3000AK01 Air Cap Retaining Outside Ring FRP Round 1 2 3000AK...

Page 16: ...3000 User Manual Installation Installation of Flat FRP Nozzle 1 3 4 6 5 3 2 1 Note Air Flow Regulating Knob Flat nozzle only Note Using 6PT metric Hand Socket 12 mm to open Hammer Front Seat Hammer Fr...

Page 17: ...o gap between metal and plastic Using 6PT metric Hand Socket 8 mm Note Make sure no gap between nozzle and gun Using 6PT metric Hand Socket 8 mm Note Using 6PT metric Hand Socket 8 mm to close head of...

Page 18: ...P 18 OTS 3000 User Manual Installation Installation of Flat FRP Nozzle 3 How to disassemble Flat nozzle 1 2 3 4 Note Using 6PT metric Hand Socket 8 mm to open metal head of flat nozzle...

Page 19: ...Front Seat in gun Make sure no gap between Hammer Front Seat and gun How to change Flat nozzle to Round TIN and FRP nozzles on electrostatic spray gun Hammer Front Seat 1 2 3 After these steps please...

Page 20: ...Approver Date Version Drawing OTS 3000 3000AQ Flat FRP Nozzle Parts List Table Figure 1 NUM Part Description Qty pcs 1 3000AQ01 Air Cap FRP Flat 1 2 3000AQ02 Air Cap Retaining Outside Ring FRP Flat 1...

Page 21: ...P 21 OTS 3000 User Manual Installation ELECTROSTATIC POWER SUPPLY A Air Inlet B Air Ball Valve C Air Regulating Valve D H V Generator E Air Outlet F H V Cable Socket A B C E F D...

Page 22: ...ual Installation LIQUID ELECTROSTATIC SPRAY GUN G Tin Nozzle M Handle H FRP Nut N Base I Gun Barrel Unit O Trigger J Hook Unit P Air Tube K Air Flow Regulating Knob R HV Cable L Paint Regulating Knob...

Page 23: ...P 23 OTS 3000 User Manual Installation ASSEMBLY glass Insert glass Check 110 240 AC Voltage Switch Inside Electrostatic Power Supply Electrostatic Power Supply...

Page 24: ...ord Socket Connected with the power source E Air Outlet Connected with the P air tube F HV Cable Socket Connected with the R HV Cable T Earthing Wire Connected with the earthing wire S Teflon Spray Tu...

Page 25: ...dicator will light the HV liquid electrostatic remains inactive Pull the trigger of the spray gun and the air will be jetted out from the tin nozzle At this time the yellow indicator lights up and the...

Page 26: ...enclosing effect Under HV output such conductive paint tends to produce large amounts of electrons which flow back to the pump or paint bucket through the paint tube thus activating the current inter...

Page 27: ...have to use Copper Ground Rod to touch paint tank when you want to change waterborne coatings or tounch paint tank and air pump it will prevent that you are not injure by electric shock OTS 3000 User...

Page 28: ...and paint from the front end of nozzle If residual air is remained in the paint tube the paint will be sprayed in intermittent state In this case continue pulling the trigger until the paint flows out...

Page 29: ...per scale of spray scope is achieved Pull the trigger Adjust the air flow regulating knob on the left side of spray gun to confirm proper atomization is achieved Turn on the power of liquid electrosta...

Page 30: ...nt is too low 3 Adjust the resistance value of paint to 20 30M 4 The sprayed object is poorly grounded 4 Confirm that the sprayed object is properly grounded 5 The exhaustion of the rinsing cabinet is...

Page 31: ...pe of atomizing equipment and by the way the equipment is controlled An electrostatic spray system should balance paint particle velocity and electrostatic voltage to optimize coating transfer efficie...

Page 32: ...S 3000 electrostatic power supply and gun are full range ability If the high and low resistivity conductivity paints are used with our gun you have to adjust the electrostatic power meter until you ca...

Page 33: ...How to coating and paint plastic products Ans In the plastic product it is applied a conductive primer but it is black dark grey due to the metallic loads Then you can coating your plastic products b...

Page 34: ...r a service center OTSON Technologies Corp or your Reseller will also manage and install selected engineering changes that apply to the Machine Some parts of OTSON Technologies Corp Machines are desig...

Page 35: ...P 35 NOTE...

Page 36: ...3000 PFL A OTS 3000 PFL B OTS 3000 GTFL OTS 3000 GTFL A OTS 3000 GTFL B OTS 3000 SF B OTS 3000 SF OTS 3000 ST A OTS 3000 GTFL B Manual Electrostatic Round Round Flat High Voltage Cable 5 0 m High Volt...

Page 37: ...ww otson com e mail sales otson com Tel 886 2 2659 7162 Fax 886 2 2656 0287 The appearance of all products detail figure and specification are subject to change at any time without notice Copyright 20...