3 Basic safety information
Read these operating instructions before using the OTT ecoLog 800 (3G) for
the first time! Become completely familiar with the installation and operation of
the OTT ecoLog 800 (3G) and its accessories! Keep these operating instructions
for later reference.
The OTT ecoLog 800 (3G) is designed to measure groundwater levels, the
water temperature and the specific conductivity of the groundwater and to
transmit these measured values through a GSM cellular network. Only use the
OTT ecoLog 800 (3G) as described in these operating instructions!
For further information
➝
refer to Chapter 4, "Introduction".
Please note all safety and warning information given within the individual work
steps. All safety and warning information given in these operating instructions
are marked by the following adjacent warning signals:
–
Black warning triangle
➝
warning of potential damage to the unit,
reduced functionality and particularly noteworthy points.
–
Black warning triangle with yellow background
➝
there is a
health hazard! Detailed information on the hazard including information on
how to prevent the hazard and possible consequences of non-observance.
Ensure the electrical, mechanical, and climatic specifications listed in the technical data
are adhered to. For further information
➝
refer to Chapter 23, "Technical data".
When operating the OTT ecoLog 800 (3G), keep a minimum distance of
0.2 metres between radio antennae and
– people, as well as
– other electrical equipment/antennae
Handle the pressure probe cable with care. Do not kink the cable or pull it
across sharp edges!
Do not make any changes or retrofits to the OTT ecoLog 800 (3G)! If changes
or retrofits are made, all guarantee claims are voided.
Have a faulty OTT ecoLog 800 (3G) inspected and repaired by our repair
center. On no account carry out repairs yourself!
For further information
➝
refer to Chapter 21, "Repair".
After putting the unit out of service, properly dispose of the OTT ecoLog 800 (3G).
On no account put the OTT ecoLog 800 (3G) into the normal domestic waste. For
further information
➝
refer to Chapter 22, "Note about the disposal of used units".
Federal Communications Commission (FCC) Approval
Note: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Oper -
ation of this equipment in a residential area is likely to cause harmful interference in
which case the user will berequired to correct the interference at his own expense.
Industry Canada Approval
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
CAUTION
Risk of burns! Hot device surface at higher ambient temperatures!
The metal parts of OTT ecoLog 800 (3G) device surface can get very hot at
higher ambient temperatures
1)
. This may lead to burns.
Use protection gloves during installation and maintenance at higher
ambient temperatures
1)
!
1)
> approx. 60 °C / 140 °F