26
Call the Observer function as follows
Start the OTT Orpheus Mini operating program.
Set up the PC/OTT Orpheus Mini communication link (see Chapter 7.2).
Depending on the option set: In the start window of the OTT Orpheus Mini
operating program, either select "View Instantaneous values" or "Setup Device"
and in the subsequent window select the "View Instataneous values" function in
the "OTT Orpheus Mini" menu
➝
the OTT Orpheus Mini starts an instanta-
neous value measurement and the "Observer" window opens:
If necessary: Input Observer registration into the entry field of the pressure
sensor and click on the "Store" button.
If necessary: Start new instantaneous value measurement: click on the "Refresh"
button ("
Automatic refresh" starts an instantaneous value measurement
every 5 seconds).
End the Observer: click on the "Exit" button and close the OTT Orpheus Mini
operating program.
Notes
The OTT Orpheus Mini stores each call of the Observer function in an info
channel with the date and time of day. After reading in and accepting into the
OTT Hydras 3 user software, this information can be displayed in the evalua-
tion window of a sensor using the "Info Data" > "Station" > Show" function
("Observer registration general"). They are likewise visible via the "View/Export
data" > "Table" function of the OTT Orpheus Mini operating program.
If the "
Do not calculate manual input value with scaling" check box in the
"Options" window is activated, the OTT Orpheus Mini also stores the input
check value, as well as the current instantaneous value. After reading in and
accepting into the OTT Hydras 3 user software, this information can be dis-
played in the evaluation window of a sensor using the "Info Data" > "Sensor" >
"Show" function ("Observer registration with check value). They are likewise
visible via the "View/Export data" > "Table" function of the OTT Orpheus Mini
oper ating program.
Fig. 15: Display/input window
"OTT Orpheus Mini operating
program – Observer".
The window displays the current instanta-
neous value for all measurements. Further-
more, the window displays the sensor
number/name, the current battery voltage,
the amount of power used from the batteries
up to now, and the date and time.