03/2010
B500 | B500-S
Page 98
Technical Data
Driving data
Speed
6 km/h or 10 km/h
Climbing ability
17 %
Obstacle height that
can be cleared
5 cm
Distance range
approx. 35 km
Operating temperature
range
-25 °C to +50 °C
Transport and storage
temperature range
-40 °C to +65 °C
Battery charger
Model
MEG 2409
Automatic battery charger
with computer-controlled
characteristic curve
Power requirements
230 V -10 %; +6 %
Mains frequency
50 Hz ±4 %
Protective system
1 (protective conductor)
Charging connection
24 V DC
Nominal charging
current
9 A
Battery charger
Residual ripple
>1 %
Characteristic curve
IUU with trickle charging
phase, computer-controlled
Primary fuse
T4G fuse link, not acces-
sible from outside
Secondary fuse
Electronic, reversible
reverse battery protection,
short circuit-proof,
idling-proof, overheating
protection
Protective system
IP 21
Ambient temperature
range
-10 °C to +40 °C
Indicator
2 LEDs
Weight
1.7 kg
Dimensions
(W x H x D)
105 x 65 x 205 mm
Table 2 Technical data