Otto Heuss GmbH 

Amtsgerichtsstr. 12 

35423 Lich, Germany 

 

+49 6404 9169 0 

info@ottoheuss.com  

 

Software Version 1.3.2 

Mounted-Hardware Version Rev.5 

PlugIn-Hardware Version Rev.7 

 

Date of issue: 04.03.2020

 

 

Page 1

 

User manual 

for OTTO HEUSS universal stop motor PCB 

RM-2  

 

For the operation of:  

Stop action sliders (el.), dual stop action sliders (el./mech), couplers and 

tremulants, with 14V and 24V direct voltage (DC) and alternating voltage (AC) 

 

Order number 4056-850  

Type 

plug-in PCB

 

 
 
 
 
 
 

Order number 4056-800  

Type 

mounted PCB

 

 

 

Summary of Contents for PCB RM-2

Page 1: ...rdware Version Rev 7 Date of issue 04 03 2020 Page 1 User manual for OTTO HEUSS universal stop motor PCB RM 2 For the operation of Stop action sliders el dual stop action sliders el mech couplers and...

Page 2: ...ts couplers and much more in 14V and in 24V in both DC and AC voltage To simplify the variants and to create new or improve existing functions the circuits will in future only be divided into two vari...

Page 3: ...pective manual of the switch cabinet 4 Electrical connection 4 1 Mounted PCB All connection terminals are designed with push in connection technology This allows rigid conductors or flexible conductor...

Page 4: ...al pulse is required AB OFF Connection for the signal to switch off the motor this is only used for the electrical mechanical dual stop action version otherwise no cable connection required Input can...

Page 5: ...must be connected to the two Schalter Switch connection points on the side of the board Switch 5 If this switch is set to ON the inputs Setzer AN Setter ON and Setzer AB Setter OFF operate by a negat...

Page 6: ...gan is switched on the motors automatically energize one side to match the ACTUAL state of the sliders to the SET state of the switches 6 2 Dual electrical mechanical stop action motor Combination of...

Page 7: ...orce when the coupler is activated The buttons AN ON and AB OFF can be used to test the coupler setup After pressing ON the coupler remains switched on until AB is pressed 6 4 Tremulant motor Tremulie...

Page 8: ...and stably fastened due to high workloads An organ is an electrical installation and must be wired connected and commissioned professionally and in accordance with applicable standards and regulations...