background image

www.oulighting.com

 

 

Copyright  © 2014. All rights reserved. 

 

R201406-V12 

 
Installation Instructions: 

 

1.  Remove splice compartment cover from fitter. 
2.  Route supply leads through fitter and into splice compartment. 
3.  Slip lower fitter over pipe or tenon and securely tighten both set screws with 5/32 allen wrench to 140 in. lbs. 
4.  Complete the wiring to the power source and ground (refer to Fixture Wiring) inside splice compartment. 
5.  TO AIM FIXTURE: With splice compartment cover removed, loosen fitter bolt. 
6.  Adjust fixture to desired angle. 
7.  Retighten fitter bolt ensuring that the upper and lower fitters are engaged. Tighten fitter bolt to 230 in. lbs. with a torque 

wrench. 

8.  Replace splice compartment cover.

 

 
 

Fixture Wiring: 

 

1.  Using customer supplied 90°C minimum rated wire connectors, make the following electrical connections: 

a.  Connect the black fixture lead to the voltagesupply lead 
b.  Connec t the white fixture lead to the neutral supply lead 
c.  Connect the green or green/yellow ground lead to the supply ground lead. 

 
 
 

Model 

EHL6S11K 

Input Voltage 

Universal 120V ~ 277V 

Delivered Lumen Output 

11,500 Lumens 

Beam Angle / Photometric Distribution 

20° Spot 

CCT 

5000K 

Color Rendition 

70 CRI 

Lifetime (L

70

 at 15°C) 

50,000 Hours 

Housing Material 

Die-cast aluminum housing and lens frame 

Finish 

Dark-bronze polyester powder-coat finish 

Minimum Starting Temperature 

-40°F 

Dimensions 

17" H x 15-7/8" W x 6-3/4" D (Height dimension includes fitter) 

Weight 

19.5 lbs 

Comparable To 

400W MH 

 

*Specifications and appearance are subject to change without notice. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

MADE IN CHINA 