Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS
14/35
©TANSUG MAKİNA LTD. 2008
4. INSTALLATION OF PANELS
4.1 Placement of Panels:
The panel should face the direction of the equator. Panel should face
South in the Northern and North in the Southern Hemispheres. Use a compass to determine
the true south.
4.2 Panel Angle:
The general application is that the panel is installed at the same angle as the
latitude of your location at all locations outside of the Tropic Zone. In complying to this rule,
a discrepancy of plus or minus 15 degrees is acceptable. Decreasing the angle will increase
the summer-time energy output while increasing will increase the winter time energy output.
4.3 Avoiding Shades:
Shades are one of the biggest threats to your system’s energy output.
Make sure that the panels are not shaded especially between 10:00 - 15:00 when the sun is
most powerful. During a summer-time installation take into account that shades will grow
bigger during winters.
4.4
Refer to the “Shading Scheme” below, for the assembly of multiple units.
DISTANCES
UNIT MODEL
121-151
191-192-302
B
A X 1,85
C
D X 1,50
D
35°
1660 mm.
1760 mm.
45°
1930 mm.
2030 mm.
E
35°
1980 mm.
45°
1749 mm.