9
9
9-1. Loose the table connection then lift it to the top of main pole and
tight again.
9-2. Bring up the tank housing and rest it on the post plate.
9-3. Connect the regulator to the gas tank and tighten it with adjustable
wrench.
9-4. Connect the end thread of inlet gas hose to the regulator.
9-5. Put LPG gas tank on the stand.
Gas connections on the heater are leak tested at the factory prior to shipment. A
complete gas tightness check must be performed at the installation site due to
possible mishandling in shipment or excessive pressure being applied to the
heater.
•
Make a soap solution of one part liquid detergent and one part water. The soap
solution can be applied with a spray bottle, brush or rag. Soap bubbles will appear
in case of a leak.
•
The heater must be checked with a full cylinder.
•
Make sure the safety control valve is in the OFF position.
•
Turn the gas supply ON.
•
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the
gas supply on and recheck.
•
Never leak test while smoking.
LEAKAGE TEST
Regulator
Gas tank