background image

- 1 -

CAUTION

PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE OPERATION.

Do not use the patio heater for indoors, as it may cause personal injury or property damage.

This outdoor heater is not intended to be installed on recreational vehicles and/or boats.

Installation and repair should be done by a qualified service person.

Improper installation, adjustment, alteration can cause personal injury or property damage.

Do not attempt to alter the unit in any manner.

Never replace or substitute the regulator with any regulator other than the factory-suggested replacement.

Do not store or use gasoline or other flammable vapors or liquids in the heater unit.

The whole gas system, hose, regulator, pilot or burner should be inspected for leaks or damage before

use, and at least annually by a qualified service person.

All leak tests should be done with a soap solution.  Never use an open flame to check for leaks.

Do not use the heater until all connections have been leak tested.

Do not transport heater while it’s operating.

Do not move the heater after it has been turned off until the temperature has cooled down.

Keep the ventilation opening of the cylinder enclosure free and clear of debris.

Do not paint the radiant screen, control panel or top canopy reflector.

Control compartment, burner and circulation air passageways of the heater must be kept clean.

Frequent cleaning may be required as necessary.

The LP tank should be turned off when the heater is not in use.

Check the heater immediately if any of the following occurs:

-

The heater does not reach temperature.

-

The burner makes popping noise during use (a slight noise is normal when the burner is extinguished).

-

Smell of gas in conjunction with extreme yellow tipping of the burner flames.

The LP regulator/hose assembly must be located out of pathways where people may trip over it or in

area where the hose will not be subject to accidental damage.

Any guard or other protective device removed for servicing the heater must be replaced before operating the heater.

Adults and children should stay away from high temperature surface to avoid burns or clothing ignition.

Children should be carefully supervised when they are in the area of the heater.

Cl

To change the gas cylinder in a amply ventilated area, away from any ignition

source (candle, cigarettes, other flame producing appliances, ...);

To check that the regulator seal is correctly fitted and able to fulfill its function

showed as photo right;

To not obstruct the ventilation holes of the cylinder housing;

To close the gas supply at the valve of the gas cylinder or the regulator after use;

In the event of gas leakage, the appliance shall not be used or if alight, the gas supply

shall be shut off and the appliance shall be investigated and rectified before it is used again;

To check the hose at least once per month

ˈ

 each time the cylinder is changed

ˈ

or each time before long time no use.

If it shows signs of cracking, splitting or other deterioration it shall be exchanged for new hose of the same length and of the

equivalent quality;

The use of this appliance in enclosed areas can be dangerous and is PROHIBITED;

Read the instructions before using this appliance. The appliance must be installed in accordance with the instructions and

local regulations.

For connection of hose and regulator,and connection of regulator and hose, please refer to photo showed above.

othing or other flammable materials should not be hung on the heater or placed on or near the heater.

T

Regulator connection: tighten connection and perform another leak test. If bubbles continue appearing 

should be returned to hose’s place of purchase. If leak is at Regulator/Cylinder Valve connection: disconnect, 

reconnect, and perform another leak check. If you continue to see bubbles after several attempts, cylinder 

valve is defective and should be returned to cylinder’s place of purchase.

urn off the gas valve immediately if smell of gas is detected. Turn Cylinder Valve OFF.If leak is at Hose/

Hose/ Regulator connection and
Regulator / Cylinder connection

seal

hose

regulater

cylinder

Summary of Contents for OUT370663/PH500

Page 1: ...as 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier or your fire Department FOR YOUR SAFETY 1 Do not store or use gasoline or other fl...

Page 2: ...icinity of this or any other appliance 2 An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNlNG 1 For use outdoors or in amply ventilated areas...

Page 3: ...st meet the following requirements Purchase LP tanks only with these required measurements 31 8cm diameter x 58 cm tall with 15kg capacity maximum In case of violent wind particular attention must be...

Page 4: ...F CONTENTS Caution 1 Heater Stand and Location 2 Gas Requirements 2 Leakage Test 2 Operation and Storage 3 Cleaning and Care 4 Parts and Specifications 4 Assembly Parts and Procedures 6 Problems Check...

Page 5: ...tive device removed for servicing the heater must be replaced before operating the heater Adults and children should stay away from high temperature surface to avoid burns or clothing ignition Childre...

Page 6: ...of liquid petroleum gases A dented rusted or damaged tank may be hazardous and should be checked by your tank supplier Never use a tank with a damaged valve connection The tank must be arranged to pr...

Page 7: ...sition then to PILOT position You should hear a clicking sound 4 Keep the control knob depressed last for 60 seconds then turn the control knob back to OFF position 5 Repeat step 3 several times until...

Page 8: ...le or corrosive Remove debris from the burner to keep it clean and safe for use Cover the burner unit with the optional protective cover when the heater is not in use PARTS AND SPECIFICATIONS 4 1830 m...

Page 9: ...ove C Table of injector APPLIANCE CATEGORY TYPES OF GAS Butane Propane GAS PRESSURE 28 30mbar 37 mbar 30 mbar 50mbar 37mbar TOTAL HEAT INPUT Hs Qn 11kW G30 800g h G31 786g h INJECTOR SIZE The marking...

Page 10: ...ion for leakage test Parts List Upper Protective Mesh N O I T P I R C S E D T R A P QUANTITY A Reflector 1 B 1 Mesh C 1 D Heating Body E Gas Hose F 1 1 G H 1 Base Cylinder Housing Wheel 1 1 Reflector...

Page 11: ...HARDWARE CONTENTS shown actual size AA BB DD CC Wing nut Qty 3 Washer 6 Qty 15 Screw M5 X 10 Qty 11 Stud Qty 3 Philips screwdriver Qty 1 Wrench Qty 1 II EE Ground Fixer Qty 3 FF Bolt M6 x 10 Qty 6 GG...

Page 12: ...sed 1 To protect heater from strong wind anchor the base securely to the ground with screws Reverse the base fix the ground fixer to the base with bolt M6X10 and washer 6 like picture shows Secure the...

Page 13: ...the Heating Body using 3pcs screw M5X10 DD HH x 3 x 1 Philips screwdriver Screw M5X10 Hardware Used 3 Assemble the heating body Secue the heating body to the tank housing using 4pcs screw M5X10 DD HH...

Page 14: ...ng 3pcs wing nut and 3pcs washer x 3 x 3 x 9 AA BB Wing nut Washer 6 CC Stud 5 Assemble the upper protective mesh to the heating body directly CAUTION Do not hang clothing or any other flammable mater...

Page 15: ...rfaces or it may melt and leak causing a fire After the cylinder is placed inside the heater secure the cylinder with block belt tightly 8 Leak Check 7 Regulator Cylinder Hose Regulator WARNING of the...

Page 16: ...s Thermocouple bad Replace thermocouple Gas leak in line Check connections Lack of fuel pressure Tank near empty Refill LPG tank B If the appliance is in case of any defaults or problems of assembly o...

Page 17: ...lector Fat fires are not covered under warranty Any warrany guarantee claims shall be rendered void in the event of improper use of the heater or the use of non approved fuels discolouration rusting o...

Reviews: