WARNING 

After consulting the manual and following instructions, remember; before 

operating, all gas connections must be fully checked for leaks 

 

IMPORTANT 

Please consult your Crystal Fire instruction manual for detailed 
instructions and important information related to the burner 
installation including: lighting and operating instructions, safety 
information, and proper tightening of connections with two wrenches.  

DO NOT ATTEMPT TO INSTALL CRYSTAL FIRE BURNER WITHOUT 
FIRST CONSULTING THE CRYSTAL FIRE OWNER’S MANUAL. 

 

Supercast Glass Fiber Reinforced Concrete (GFRC) Products Warranty Information 

 

One year warranty on structure and finish.  Cracks that exceed ⅛’’ displacement in 
either height or gap and determined to be a product of either material or 
workmanship, shall be warrantied for a period of 1 year.  Non-structural hairline 
cracks are possible, and shall not be considered a manufacturing defect. 

 

Natural variations in color, shade, porosity, and texture may occur with GFRC 
products and are considered inherent and valued qualities of the material.  Variation 
in shape and dimension can be up to ± ¼”. 

 

Under most conditions, re-sealing is suggested every 1-2 years using a clear matte 
finish solvent based concrete sealer. The frequency is dependent on ambient 
conditions including, but not limited to: frequency of use, exposure to UV, saltwater, 
chlorine, hard water, air temperature, and humidity. 

 

If covering a GFRC item, use a one-way breathable cover as approved and supplied 
by OGC.  Do not use other materials or objects in order to hold down or secure a 
protective cover on top or around the GFCR item. 

 

While maintaining a regular re-sealing maintenance schedule in combination with 
using an OGC one-way breathable cover, the color of a GFRC item will fade 
minimally over time and should not require re-staining or re-coloring.  If re-staining, 
contact OGC for an approved stain type and color. 

 

Summary of Contents for Alcott ALC-1224

Page 1: ...Alcott Fire Table Installation Instructions for ALC 1224 ...

Page 2: ...s Leather Gloves To protect hands from rough edges found on fire pit during installation One AAA Battery not included Required for electric spark igniter installation Utility Knife To cut and remove packaging IMPORTANT Please consult your Crystal Fire instruction manual for detailed instructions and important information related to the burner installation including lighting and operating instructi...

Page 3: ...trol Panel Installed ALC 1224 BASE Antique Timber Supercast Top and Burner Cover 3648 1224 AT 3648 1224 AT C 1224 Crystal Fire Plus Burner with Brown Trim CFP 1224 BRN Refer to Crystal Fire Plus Manual for items included with Crystal Fire Plus burners ...

Page 4: ...ncluded manuals in a safe place for future reference 2 Base Placement Place base in desired final location Place on a hard flat surface Avoid soft surfaces and areas that collect water Refer to Crystal Fire Plus Manual included with your Crystal Fire Plus Burner for safety information regarding the placement of your fire pit ...

Page 5: ...below Depress CF SPARKER button to test your sparker 4 Supercast Top Placement Caution Top is heavy two people are required to lift and set in to place Remove burner cover before lifting the top to avoid damage to the cover Construction adhesive can be used to permanently secure top to base if desired Locate and orient sparker box on control panel as shown Sparker box must be installed before burn...

Page 6: ... the factory Check all connections for leaks If needed tighten connection with 2 wrenches and re check for leaks Attach burner valve to control panel with provided screws as shown below Ensure sparker box is installed before this step Carefully place burner into burner opening oriented as shown Electrode Access door ...

Page 7: ...ect Spark Ignition system only Test system by pushing the button on the igniter Consult the troubleshooting section of the Crystal Fire Plus Burner Owner s Manual if the spark is weak intermittent or not present 6 Thermocouple Installation Refer to Crystal Fire Plus instruction manual for detailed attachment of thermocouple Attach thermocouple to burner valve as shown below ...

Page 8: ...e off attach the propane regulator to the propane tank Hand tighten do not use a wrench for this connection Insert propane tank into base by sliding it past the red dotted line shown above Ensure no hoses or wires are contacting the bottom of the burner Replace the access door ...

Page 9: ...glass beads lava rock or other approved fire media evenly across entire burner surface DO NOT OPERATE CRYSTAL FIRE PLUS BURNER WITHOUT INCLUDED GLASS BEADS OR OTHER APPROVED FIRE MEDIA DO NOT OPERATE CRYSTAL FIRE PLUS BURNER WITH BURNER COVER IN PLACE ...

Page 10: ...or inlet side of the valve If leak is detected immediately shut off the gas supply and wait 5 minutes to allow gas to dissipate Fix any leaks before proceeding Press the sparker button and hold look and listen for spark between electrode and grounding rod While depressing the sparker open the valve If burner does not light after 10 seconds close the valve and wait 5 minutes to allow gas to dissipa...

Page 11: ...possible and shall not be considered a manufacturing defect Natural variations in color shade porosity and texture may occur with GFRC products and are considered inherent and valued qualities of the material Variation in shape and dimension can be up to Under most conditions re sealing is suggested every 1 2 years using a clear matte finish solvent based concrete sealer The frequency is dependent...

Page 12: ...with pride in the USA 14400 Southcross Drive West Suite 100 Burnsville MN 55306 Toll Free 1 866 303 4028 Sales OutdoorRooms com Warranty Fire pit tables are covered under a 1 year manufacturer s warranty Please visit https www outdoorrooms com product registration to register your product ...

Reviews: