7
7.
Electrode Installation
Plug both BLACK wires hanging from the
burner into the back of the CF-SPARKER. If
an orange wire is present, do not use it. The
orange wire is for Direct Spark Ignition
system only.
Test system by pushing the button on the
igniter. Consult the troubleshooting section
of the Crystal Fire Plus Burner Owner’s
Manual, if the spark is weak, intermittent,
or not present.
6.
Thermocouple Installation
•
Refer to Crystal Fire Plus instruction manual
for detailed attachment of thermocouple.
•
Attach thermocouple to burner valve as
shown below.