A. Before Lighting Appliance
LP (Propane) and NG (Natural Gas)
Before lighting this appliance, ensure both the LP tank valve
and the manual shutoff valve are closed. Open the LP tank
valve first, THEN the manual shutoff valve. This is required due
to built-in safety features of your LP tank.
Before operating the appliance, have a qualified
technician:
Inspect the burner. Remove or clean any debris that may
have fallen on the appliance. If a thorough cleaning is
required, remove the glass material and wipe off burner
surface making sure all burner ports are free of debris. If
there is any evidence that the burner is damaged, replace
it with an approved replacement part.
Check the air shutter adjustment.
Ensure that there are no gas leaks. Inspect all gas
supply lines. If there is evidence of excessive abrasion wear,
or any damage, replace those components with approved
replacement parts.
Ensure that the flow of combustion and ventilation air is not
obstructed.
6
Operating Instructions
Confirm sparker is producing spark prior
to turning gas on.
Improper installation, adjustment, alteration service, or
maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this
appliance. For assistance or additional information consult
a qualified installer, service agency, or the gas supplier.
WARNING
WARNING