background image

Page | 14                   

www.outdoorrooms.com

   

 

 CF-1242 AU Rev-E 8/24/15 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 6     

Lighting and operation 

    

A.

This appliance is lit electronically. When lighting, follow 
these instructions exactly.  

B. Before lighting, 

smell all around the appliance area for 

gas. Be sure to smell next to the base of the appliance 
because some gas is heavier than air and will settle on 
the floor. 

 

WHAT TO DO IF YOU SMELL GAS: 

Do not try to light any appliance.

 

Do not touch any electric switch, do not use any phone 
nearby. 

 

Immediately call your gas supplier from a neighbor’s 
phone. Follow gas supplier’s instructions. 

 

If you cannot reach your gas supplier, call the fire 
department

 

FOR YOUR SAFETY, READ BEFORE LIGHTING 

WARNING! 

If you do not follow these instructions exactly, a fire or explosion may result 

causing property damage, personal injury, and/or loss of life. 

C. 

Use only your hand to turn the gas control knob 

on gas supply (if equipped), never use tools. If the 
valve won’t turn by hand, don’t try to repair it, call 
a qualified service technician. Force or attempted 
repair may result in a fire or explosion.  

D. 

Do not use the appliance if any part has been 

underwater. Immediately call an authorized service 
technician to inspect the appliance and replace any 
part which has been underwater.  

Lighting Instructions 

1. 

Turn on/off switch to ON position.  

2. 

You will see or hear sparking occurring at the 

electrode 

In the event the flame does not light: 

flip switch to the OFF position, wait 10 minutes, 

and re-attempt ignition.  

Initial break-in procedure:

      

When you light the appliance, you may notice that it produces heat 

which may have an odor. If you feel this odor is excessive it may require an initial three to four hour 

continuous burn. 

 

 

 

 

    

Summary of Contents for CF-1242-AU-N, CF-1242-AU-LP

Page 1: ...call the fire department Installation and service must be performed by authorized personnel HOT DO NOT TOUCH SEVERE BURNS MAY RESULT CLOTHING IGNITION MAY RESULT Glass and other surfaces are hot duri...

Page 2: ...ce The fire pit burner you have selected is designed to provide the utmost in safety reliability and efficiency As the owner of an Outdoor GreatRoom Company fire pit you ll want to read and carefully...

Page 3: ...ation 7 Troubleshooting 8 ServiceandMaintenance 9 ReferenceMaterials a ServicePartsList b DimensionalInformation c CheckingTestPointPressure d WiringDiagram e LimitedOneYearWarranty CF 1242AU N 305mm...

Page 4: ...ired Outdoor Fireplace Burner STANDARD AS4558 AS4565 Crystal fire burner has been tested in accordance with IAS requirements for Outdoor Gas Fireplaces AS4558 AS4565 and operation as described in thes...

Page 5: ...r and the warranty will be voided by the following actions Installation and use of any damaged components Modification of the burner assembly Installation other than as instructed by the Outdoor Great...

Page 6: ...from top of metal bowl 6M 6M 1 8M If you are not using an Outdoor GreatRoom Company table with this burner be sure to mount to a non combustible surface maintaining at least 2M to combustible surface...

Page 7: ...areas have been used in these figures the same principles apply to any other shaped area This appliance shall only be used in an outdoor area and shall not be used in a building garage or any other e...

Page 8: ...overhead cover Within a partial enclosure that includes an overhead cover and no more than two walls Within a partial enclosure that includes an overhead cover and more than two walls the following sh...

Page 9: ...Page 9 www outdoorrooms com CF 1242 AU Rev E 8 24 15...

Page 10: ...LP installations are to be hard plumbed using rigid piping only B Glass Beads Installation Spread glass out evenly over burner area Use all glass provided for best effect Keep glass clear of spark to...

Page 11: ...l manual shutoff valve during any pressuretestingofthegassupplypipingsystemattestpressures equal to or less than 3 5 kPa C Gas Connection Note Have the gas supply installed in accordance to AS NZS5601...

Page 12: ...te the gas line not supplied and tighten securely to output valve fitting following the method described in step 2 4 Using two wrenches securely tighten the flare nut on the free end of the metal flex...

Page 13: ...ol valve following the same process 3 Connect the incoming Natural Gas supply line to the incoming side of the regulator using an elbow connection Gas supply line must be a minimum of 12 7mm piping 4...

Page 14: ...n may result causing property damage personal injury and or loss of life C Use only your hand to turn the gas control knob on gas supply if equipped never use tools If the valve won t turn by hand don...

Page 15: ...____________________________________________________________________ ______________________________________________________________________ WARNING FIRE RISK HIGH TEMPERATURES Keep combustible househo...

Page 16: ...s it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance Do nothing 4 Decorative Beads cracking or...

Page 17: ...ing used 5 Inspect injector for soot dirt or corrosion 6 Verify inlet and test point pressures Adjust regulator as required 8 Service and Maintenance Although the frequency of appliance servicing and...

Page 18: ...lass for Crystal Fire burner 5lb bag 8 Grounding wire for crystal fire All models SPK GND 9 Control Valve AU 10 Control Box AU 12 Battery pack for valve system 13 Glass guard kit GG1242 AU Optional Ac...

Page 19: ...and constructing a base for this burner Be sure to plan enough space to install a manual shutoff valve before gas reaches the control valve on the burner Dimensions approximate Always measure before...

Page 20: ...d disconnect the fire pit from gas supply before anything is done to electrical components LP Natural gas OUT IN Ideal test point pressures In 2 75kPa 1 13kPa Out 1 75kPa 5kPa I S Gas valve Battery Pa...

Page 21: ...lly discharge its obligations under this warranty by repairing or replacing at its discretion the defective components The Outdoor GreatRoom Company will provide replacement parts at no charge and wil...