Page | 16
www.outdoorrooms.com
CF-1242 AU Rev-E 8/24/15
Symptom
Possible Causes
Corrective Actions
1.
Burner won’t
light.
A.
No fuel
Check gas valve at main.
B.
Plugged burner injector.
Check the burner injector for stoppage. Remove
stoppage.
2.
Blue Flames
A.
This is a result of normal operation and
flames will begin to yellow as unit is
allowed to burn for 16-20 minutes.
Do nothing.
B.
Improper air/fuel mixture related to air
shutter position.
Close air shutter. (for LP, leave 7mm open, Natural
gas 1.5mm open)
3. Metallic noise
A.
Noise is caused by metal expanding
and contracting as it heats up and
cools down, similar to the sound
produced by a furnace or heating
duct. This noise does not affect the
operation or longevity of the
appliance.
Do nothing.
4.
Decorative Beads
cracking or splitting
A.
Heat and/or abrupt temperature
changes.
This is a property of glass and may happen
occasionally. Do nothing. This is completely normal.
5.
Sparker makes
clicking sound but
no visible spark is
produced
A
Sparker is improperly grounded
Refer to section 4-C on Page 9 for grounding
instructions. Check all wire connections.
B.
Ignition or ground wire not plugged in.
C.
Igniter tip set too far from grounding
probe
Check that tip of sparker is within 6mm of grounding
probe. Gently bend igniter tip or grounding probe by
hand to achieve a smaller gap.
7
Troubleshooting