D. LP Gas Suppl y 

 

The LP gas supply used with LP models must be constructed 
and marked in accordance with the specifications for LP gas. 

 

Cylinders must be stored outdoors in a well-ventilated area out 
of  the  reach  of  children.  Disconnected  cylinders  must  have 
threaded valve plugs tightly installed and must not be stored 
in a building, garage or any other enclosed area. 

 

 

Storage of this appliance indoors is permissible only 
if it has been disconnected from its fuel supply. 

 

The LP gas supply system must be arranged for 
vapor withdrawal. 

 

The specific size and capacity of the cylinder(s) to 
be used: hard plumbed to propane tank. 

 

Gas Setup for Liquid Propane 

1.

 

With burner in place in Outdoor 
GreatRoom Company fire pit table or other 
installation location and proper sized 
injector inserted in burner neck (see chart 
on p.4 for injector sizing),  

2.

 

Incoming propane should be hard-plumbed 
to the input of the gas control valve with an 
approved regulator for propane. Tighten 
securely using two wrenches.  

3.

 

Locate the gas line (not supplied) and 
tighten securely to output valve fitting 
following the method described in step 2.  

4.

 

Using two wrenches, securely tighten the 
flare nut on the free end of the metal flex 
hose to the injector on the burner.  

5.

 

For liquid propane installations, the air 
shutter must be left open as shown at 
lower right to prevent soot buildup. 

To 

adjust air shutter, loosen the small securing 
screw and rotate air shutter to allow more 
or less airflow.   

 

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION SERVICES, OR MAINTENANCE CAN CAUSE INJURY OR 
PROPERTY DAMAGE. REFER TO AND UNDERSTAND THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION 
CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, LICENSED TECHNICIAN OR THE GAS SUPPLIER.  

Flare Nut 

Injector 

Venturi/Air shutter

CHECK ENTIRE SYSTEM FOR LEAKS BEFORE 

OPERATING. IF AN INSTALLER IS 

CONVERTING THE UNIT FROM NATURAL 

GAS TO LP, RE-CHECK ALL CONNECTIONS 

FOR LEAKS BEFORE USE. 

Gas from 
control valve 

Burner shape may differ from your model 

Overhead view of burner and valve system 

Incoming gas 

supply (hard 

piped) 

Propane regulator 

(locate under drip 

guard) 

Gas control 

valve 

Corrugated 
metal flex-line  

Gas flow from 
valve to burner 

Gas out 

Gas in 

AN APPROVED REGULATOR MUST BE FITTED BY 

THE INSTALLING PLUMBER 

Summary of Contents for Crystal Fire CF-1242

Page 1: ...call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier HOT DO NOT TOUCH SEVERE BURNS MAY RESULT CLOTHING IGNITION MAY RESULT G...

Page 2: ...e fire pit burner you have selected is designed to provide the utmost in safety reliability and efficiency As the owner of an Outdoor GreatRoom Company fire pit you ll want to read and carefully follo...

Page 3: ...Operation 7 Troubleshooting 8 ServiceandMaintenance 9 ReferenceMaterials a ServicePartsList b DimensionalInformation c CheckingTestPointPressure d WiringDiagram e LimitedOneYearWarranty CF 1242AU N 30...

Page 4: ...er STANDARD AS4565 2004 AS4558 2011 Crystal fire burner has been tested in accordance with IAS requirements for Outdoor Gas Fireplaces AS4565 2004 AS4558 2011 and operation as described in these insta...

Page 5: ...r and the warranty will be voided by the following actions Installation and use of any damaged components Modification of the burner assembly Installation other than as instructed by the Outdoor Great...

Page 6: ...raffic areas WARNING 1 8M to overhang from top of metal bowl 6M 6M 1 8M If you are not using an Outdoor GreatRoom Company table with this burner be sure to mount to a non combustible surface maintaini...

Page 7: ...areas have been used in these figures the same principles apply to any other shaped area This appliance shall only be used in an outdoor area and shall not be used in a building garage or any other e...

Page 8: ...overhead cover Within a partial enclosure that includes an overhead cover and no more than two walls Within a partial enclosure that includes an overhead cover and more than two walls the following sh...

Page 9: ...Page 9 www outdoorrooms com CF 1242 AU Rev B 3 19 15...

Page 10: ...You must have easy access to the gas valve control knob after it is installed and connected to the gas supply LP Gas Models Make sure the valve is turned completely off before installing LP installat...

Page 11: ...f valve during any pressuretestingofthegassupplypipingsystemattestpressures equal to or less than 3 5 kPa C Gas Connection Note Have the gas supply installed in accordance with local building codes if...

Page 12: ...te the gas line not supplied and tighten securely to output valve fitting following the method described in step 2 4 Using two wrenches securely tighten the flare nut on the free end of the metal flex...

Page 13: ...ntrol valve following the same process 3 Connect the incoming Natural Gas supply line to the incoming side of the regulator using an elbow connection Gas supply line must be a minimum of 12 7mm piping...

Page 14: ...n may result causing property damage personal injury and or loss of life C Use only your hand to turn the gas control knob on gas supply if equipped never use tools If the valve won t turn by hand don...

Page 15: ...____________________________________________________________________ ______________________________________________________________________ WARNING FIRE RISK HIGH TEMPERATURES Keep combustible househo...

Page 16: ...s it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance Do nothing 4 Decorative Beads cracking or...

Page 17: ...ing used 5 Inspect injector for soot dirt or corrosion 6 Verify inlet and test point pressures Adjust regulator as required 8 Service and Maintenance Although the frequency of appliance servicing and...

Page 18: ...burner 5lb bag CF20 Glass 1 8 Grounding wire for crystal fire All models SPK GND 1 9 Control Valve AU 1 10 Control Box AU 1 11 Decorative SS Top AU 1 12 Battery pack for valve system 1 13 Glass guard...

Page 19: ...and constructing a base for this burner Be sure to plan enough space to install a manual shutoff valve before gas reaches the control valve on the burner Dimensions approximate Always measure before...

Page 20: ...d disconnect the fire pit from gas supply before anything is done to electrical components LP Natural gas OUT IN Ideal test point pressures In 2 75kPa 1 13kPa Out 1 75kPa 5kPa I S Gas valve Battery Pa...

Page 21: ...lly discharge its obligations under this warranty by repairing or replacing at its discretion the defective components The Outdoor GreatRoom Company will provide replacement parts at no charge and wil...

Reviews: