CF-1242 AU Rev-B 3/19/15
D. LP Gas Suppl y
The LP gas supply used with LP models must be constructed
and marked in accordance with the specifications for LP gas.
Cylinders must be stored outdoors in a well-ventilated area out
of the reach of children. Disconnected cylinders must have
threaded valve plugs tightly installed and must not be stored
in a building, garage or any other enclosed area.
Storage of this appliance indoors is permissible only
if it has been disconnected from its fuel supply.
The LP gas supply system must be arranged for
vapor withdrawal.
The specific size and capacity of the cylinder(s) to
be used: hard plumbed to propane tank.
Gas Setup for Liquid Propane
1.
With burner in place in Outdoor
GreatRoom Company fire pit table or other
installation location and proper sized
injector inserted in burner neck (see chart
on p.4 for injector sizing),
2.
Incoming propane should be hard-plumbed
to the input of the gas control valve with an
approved regulator for propane. Tighten
securely using two wrenches.
3.
Locate the gas line (not supplied) and
tighten securely to output valve fitting
following the method described in step 2.
4.
Using two wrenches, securely tighten the
flare nut on the free end of the metal flex
hose to the injector on the burner.
5.
For liquid propane installations, the air
shutter must be left open as shown at
lower right to prevent soot buildup.
To
adjust air shutter, loosen the small securing
screw and rotate air shutter to allow more
or less airflow.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION SERVICES, OR MAINTENANCE CAN CAUSE INJURY OR
PROPERTY DAMAGE. REFER TO AND UNDERSTAND THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION
CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, LICENSED TECHNICIAN OR THE GAS SUPPLIER.
Flare Nut
Injector
Venturi/Air shutter
CHECK ENTIRE SYSTEM FOR LEAKS BEFORE
OPERATING. IF AN INSTALLER IS
CONVERTING THE UNIT FROM NATURAL
GAS TO LP, RE-CHECK ALL CONNECTIONS
FOR LEAKS BEFORE USE.
Gas from
control valve
Burner shape may differ from your model
Overhead view of burner and valve system
Incoming gas
supply (hard
piped)
Propane regulator
(locate under drip
guard)
Gas control
valve
Corrugated
metal flex-line
Gas flow from
valve to burner
Gas out
Gas in
AN APPROVED REGULATOR MUST BE FITTED BY
THE INSTALLING PLUMBER