background image

Page | 5                   

www.outdoorrooms.com

   

 

 CF-1242 AU Rev-B 3/19/15 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2   

 

 

Getting Started

   

 

This appliance is a Decorative Gas Appliance for 

OUTDOOR USE ONLY

 and 

MUST NOT

 be used 

for cooking. 

Build or position the CF-1242AU burner system on 
a flat and stable surface in an outdoor location such 
as a patio or deck. This location must be adjacent to 
the gas supply line or LP gas supply. 

DO NOT

 

locate the appliance where it will get excessively 
wet or submerged in water. 

A.

 

Design and Installation Considerations 
 

 

 

 

  

When planning an appliance installation, it’s necessary to 
determine the following information before installing: 

 

Where will the appliance be installed? 

See section 3

 

 

Gas supply piping.                                     

See section 5

 

 

Framing and finishing details.                 

See section 3

 

B.

 

Tools and Supplies Required  

 

 

 

  

Before beginning the installation, be sure that the 
following tools and supplies are at hand.  

 

Gloves 

 

Safety Glasses 

 

Phillips screwdriver 

 

Non-corrosive leak-check solution 

 

Wrenches 

                       WARNING 

The Outdoor GreatRoom Company 
disclaims any responsibility for, and 
the warranty will be voided by, the 
following actions: 

 

Installation and use of any damaged 
components. 

 

Modification of the burner assembly 

 

Installation other than as instructed 
by the Outdoor GreatRoom 
Company. 

Any such action may cause a fire hazard 

 

 

WARNING 

Do 

NOT

 use this appliance if any part of it has 

been underwater. Have an authorized service 
technician inspect the appliance and replace 
any part of the control system and any gas 
control which has been underwater.  

CAUTION 

Sharp Edges 

     Wear protective gloves and safety glasses 
during installation. 

WARNING 

Do not burn solid fuels in this gas appliance 

 

C.

 

Inspect the Appliance and Components  
 

 

 

  

WARNING 

Inspect appliance and components for 
damage. Damaged parts may impair safe 
operation. 

Do 

NOT

 install damaged, incomplete, 

or substitute components 

Report damaged parts to your dealer. 

WARNING

 

Asphyxiation Risk 

 

This gas appliance is for outdoor use in a 
well-ventilated space. 

 

This unit must not be installed inside an 
enclosed structure or unvented appliance 

 

Carefully remove all burner 
components from packaging.  

 

Read all instructions before beginning 
installation. Follow these instructions 
carefully during installation to ensure 
maximum safety and benefit. 

Summary of Contents for Crystal Fire CF-1242

Page 1: ...call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier HOT DO NOT TOUCH SEVERE BURNS MAY RESULT CLOTHING IGNITION MAY RESULT G...

Page 2: ...e fire pit burner you have selected is designed to provide the utmost in safety reliability and efficiency As the owner of an Outdoor GreatRoom Company fire pit you ll want to read and carefully follo...

Page 3: ...Operation 7 Troubleshooting 8 ServiceandMaintenance 9 ReferenceMaterials a ServicePartsList b DimensionalInformation c CheckingTestPointPressure d WiringDiagram e LimitedOneYearWarranty CF 1242AU N 30...

Page 4: ...er STANDARD AS4565 2004 AS4558 2011 Crystal fire burner has been tested in accordance with IAS requirements for Outdoor Gas Fireplaces AS4565 2004 AS4558 2011 and operation as described in these insta...

Page 5: ...r and the warranty will be voided by the following actions Installation and use of any damaged components Modification of the burner assembly Installation other than as instructed by the Outdoor Great...

Page 6: ...raffic areas WARNING 1 8M to overhang from top of metal bowl 6M 6M 1 8M If you are not using an Outdoor GreatRoom Company table with this burner be sure to mount to a non combustible surface maintaini...

Page 7: ...areas have been used in these figures the same principles apply to any other shaped area This appliance shall only be used in an outdoor area and shall not be used in a building garage or any other e...

Page 8: ...overhead cover Within a partial enclosure that includes an overhead cover and no more than two walls Within a partial enclosure that includes an overhead cover and more than two walls the following sh...

Page 9: ...Page 9 www outdoorrooms com CF 1242 AU Rev B 3 19 15...

Page 10: ...You must have easy access to the gas valve control knob after it is installed and connected to the gas supply LP Gas Models Make sure the valve is turned completely off before installing LP installat...

Page 11: ...f valve during any pressuretestingofthegassupplypipingsystemattestpressures equal to or less than 3 5 kPa C Gas Connection Note Have the gas supply installed in accordance with local building codes if...

Page 12: ...te the gas line not supplied and tighten securely to output valve fitting following the method described in step 2 4 Using two wrenches securely tighten the flare nut on the free end of the metal flex...

Page 13: ...ntrol valve following the same process 3 Connect the incoming Natural Gas supply line to the incoming side of the regulator using an elbow connection Gas supply line must be a minimum of 12 7mm piping...

Page 14: ...n may result causing property damage personal injury and or loss of life C Use only your hand to turn the gas control knob on gas supply if equipped never use tools If the valve won t turn by hand don...

Page 15: ...____________________________________________________________________ ______________________________________________________________________ WARNING FIRE RISK HIGH TEMPERATURES Keep combustible househo...

Page 16: ...s it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance Do nothing 4 Decorative Beads cracking or...

Page 17: ...ing used 5 Inspect injector for soot dirt or corrosion 6 Verify inlet and test point pressures Adjust regulator as required 8 Service and Maintenance Although the frequency of appliance servicing and...

Page 18: ...burner 5lb bag CF20 Glass 1 8 Grounding wire for crystal fire All models SPK GND 1 9 Control Valve AU 1 10 Control Box AU 1 11 Decorative SS Top AU 1 12 Battery pack for valve system 1 13 Glass guard...

Page 19: ...and constructing a base for this burner Be sure to plan enough space to install a manual shutoff valve before gas reaches the control valve on the burner Dimensions approximate Always measure before...

Page 20: ...d disconnect the fire pit from gas supply before anything is done to electrical components LP Natural gas OUT IN Ideal test point pressures In 2 75kPa 1 13kPa Out 1 75kPa 5kPa I S Gas valve Battery Pa...

Page 21: ...lly discharge its obligations under this warranty by repairing or replacing at its discretion the defective components The Outdoor GreatRoom Company will provide replacement parts at no charge and wil...

Reviews: