outdoorrooms.com
12
OPERATING INSTRUCTIONS
IMPORTANT
WARNING
Before operating your fireplace, ensure all gas connections are properly
tightened and thoroughly leak checked. Refer to the Crystal Fire
®
Plus
manual for information on proper leak checking and other critical safety
information.
FIRE OR EXPLOSION HAZARD
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury, or loss of life.
5.
!
!
!
!
Verify control switch is in OFF position.
See Image 5.1.
If operating on a self-contained propane
cylinder, ensure cylinder valve is CLOSED. If
operating on a hard-piped system, ensure main gas
supply shut-off valve and all other valves in gas
system are OPEN.
If operating on a self-contained propane cylinder,
slowly open cylinder valve.
Turn control switch to ON position. A 1-2 second
delay will occur while control module runs diagnostics.
Sparking will then occur at the ignition electrodes.
See Image 5.2.
Gas valve will open and burner will
ignite.
If burner does not ignite within 12 second ignition win-
dow, turn control switch to OFF position and
wait 5 minutes to allow gas to dissipate before
attempting ignition again.
DO NOT ATTEMPT TO
LIGHT BURNER IF YOU SMELL GAS.
While burner is operating, the DSI system will
continuously monitor the presence of a flame. If flame
signal is lost, the system will attempt re-ignition for up
to 12 seconds. If flame signal is lost for more than 12
seconds, the system will shut down.
TO EXTINGUISH
Turn control switch to OFF position.
See Image 5.1
If using a self-contained propane cylinder, close valve.
ON
OFF
REMOTE
SPARK LOCATION
SEE DETAIL A
Image 5.1
Image 5.2
A. DSI SYSTEM