outdoorrooms.com
5
B. NATURAL GAS CONNECTIONS
For hard piped installations: Position fireplace over gas line as shown in
Image 3.1.
Connect the gas supply line (
not included
) to the 1/2” male flare
fitting on the valve.
USE TWO WRENCHES TO ENSURE A GAS TIGHT
CONNECTION.
Run gas line pipe up through large round opening in bottom of base
See Crystal Fire
®
Plus instructions for burner installation.
All gas connections were completed at the factory. Performing a leak test
on all connections is required.
It is recommended that this unit is installed as hard piped.
Check all connections for leaks. If needed, tighten connection with
two wrenches and re-check for leaks.
Image 3.1
(Cross section top view of fireplace)
•
•
•
•
•
18.50
5.81
3.50
9.25
8.50
6.00
72.00
8.50
2.75
Dimension Varies Per Skew
GAS LINE ACCESS
ELECTRICAL ACCESS