outdoorrooms.com
6
D. BURNER MAINTENANCE
Before doing any maintenance on
burner or DSI box, it is recommended to
place a protective barrier, such as a towel
or cardboard, over stainless steel caps.
Carefully lift burner out of burner pan
and rest on side caps as shown in
Image 3.3.
To access underneath burner, the access
plate coverings can be removed. Using a
phillips screwdriver, remove bolts holding
access plate to pan as shown in
Image 3.4.
Carefully lift up both access
plates and tilt inwards to remove. Take
care not to scratch stainless steel interior
side panels.
Tighten all connections with two
wrenches and perform a leak test
after any burner or DSI maintenance.
C. ELECTRICAL INSTALLATION
Feed electrical wiring up through smaller hole in base pan as shown in
Image 3.2.
Wire electrical into junction box.
Image 3.2
Cross section of fireplace.
ELECTRICAL LOCATION
Image 3.4
Image 3.3
•
•
•
•
•
PROTECTIVE BARRIER HERE
NOTE:
Not required for VCSV
equipped fireplaces.
Image 3.1
(Cross section top view of fireplace)