Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. U • 3/12
7
6 in.
6 in.
6 in. min.
36 in. min.
cement
board from
the top of the
firebox
opening
36 in. min.
noncombustible
finishing
material
82 in.
(2083 mm)
floor to ceiling
0 in.
Combustible Object
36 in.
(914 mm)
Front
Back
Note:
If this surface is
inside the building’s
warm air envelope...
...then this surface
must be an exterior
wall system.
45-1/2 in.
(1156 mm)
57 in.
(1448 mm)
minimum
1 1/2 in.
(38 mm)
56 in.
(1422 mm)
79 1/4 in.
(2013 mm)
17 in.
(432 mm)
45-1/2 in.
(1156 mm)
1 1/2 in.
(38 mm)
1 1/2 in.
(38 mm)
Control
Box
ControlBox
42 1/2 in.
(1080 mm)
minimum
header height
42 1/2 in.
(1080 mm)
minimum
header height
68 1/2 in.
(1740 mm)
minimum
to top of cement
board
44 in.
(1118 mm)
17 in.
(432 mm)
Flashing
Cement Board
Control box
MUST be
relocated!
Exterior
Interior
11 1/2 in.
(292 mm)
minimum
8-1/4 in.
(210 mm)
10-5/8 in.
(270 mm)
Framing
36 in. minimum
(889 mm)
from appliance front
Side clearances can be zero at framing,
up to 6 inches deep
Side clearances can be zero at framing,
up to 6 inches deep
6 in.
6 in.
36 in. minimum
(889 mm)
from appliance front
Note:
For actual appliance
dimensions refer to Section 12.
Figure 3.1
Appliance Locations and Framing Dimensions - CARODG36I, CARODG36IL
NOTICE:
Vinyl siding must
not be placed between the
fireplace opening and the
ceiling/overhang.
NOTICE:
Flash the perimeter of the fi replace, corners and
the fi replace face in a manner consistent with regional
practices as required to prevent water penetration around
the fi replace or manage water that may penetrate the
fi replace. See Section 3.D. for more information regarding
wall and enclosure construction.
E. Clearances and Framing Dimensions
CARODG36I, CARODG36IL