Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. U • 3/12
8
Framing
6 in. min.
82 in.
(2.08 m)
floor to ceiling
0 in.
Combustible Object
36 in.
(914 mm)
Front
Back
Note: If this surface is inside
the building’s warm air
envelope...
...then this surface must
be an exterior wall
system.
51-1/2 in.
(1.3 m)
63 in.
(1.6 m)
minimum
1-1/2 in.
(38 mm)
59-5/8 in.
(1.5 m)
82-1/4 in.
(2.1 m)
17 in.
(432 mm)
51-1/2 in.
(1.3 m)
1-1/2 in.
(38 mm)
1-1/2 in.
(38 mm)
Control
Box
Control
Box
50-1/2 in.
(1.28 m)
minimum
header height
50 in.
(1.27 m)
minimum
header height
71-3/4 in.
(1.82 m)
minimum
to top of cement
board
50 in.
(1.27 m)
17 in.
(432 mm)
Flashing
Cement Board
Control box
MUST be
relocated!
Exterior
Interior
11-1/2 in.
(292 mm)
minimum
36 in. minimum
(889 mm)
from appliance front
Side clearances can be zero at framing,
up to 6 inches deep
6 in.
6 in.
Side clearances can be zero at framing,
up to 6 inches deep
6 in.
6 in.
36 in. min. (914 mm)
cement board from
the top of the firebox
opening
36 in. min. (914 mm)
noncombustible
finishing material
8-1/4 in.
(210 mm)
10-5/8 in.
(270 mm)
36 in. minimum
(889 mm)
from appliance front
Note:
For actual appliance
dimensions refer to Section 12.
Figure 3.2 Appliance Locations and Framing Dimensions - CARODG42I, CARODG42IL
NOTICE:
Vinyl siding must
not be placed between the
fireplace opening and the
ceiling/overhang.
NOTICE:
Flash the perimeter of the fi replace, corners and
the fi replace face in a manner consistent with regional
practices as required to prevent water penetration around
the fi replace or manage water that may penetrate the
fi replace. See Section 3.D. for more information regarding
wall and enclosure construction.
E. Clearances and Framing Dimensions
CARODG42I, CARODG42IL