34
Figure 10.3 Mailbox Style Shroud Dimensions
Figure 10.4 Roofed Style Shroud Dimensions
Roofed Style Shroud (radiation shield required)
Mailbox Style Shroud (radiation shield required)
Outdoor Lifestyles by Hearth & Home Technologies • ODVILLA Wood Owners/Install • 4072-345 Rev A • 08/22
3 in. (76 mm)
Min. Opening Height
Min, Base Dim
Min. Height
above bottom of
termination
cap
Min.
Base Dim
3 in. (76 mm) Min.
Radiation Shield Height
from top of Chase
Min, Opening Width
Radiation
Shield
Minimum
Opening Height
TR344
TR342-B
TR342-B TR344/
with TR-TVK
Min. Base Dims.
in
26-1/2 x 28
28 x 30
mm
673 x 711
711 x 762
Min. Height Above Bottom of
Termination Cap
in
28-1/4
27-1/2
mm
718
698
Min. Opening Width
in
20-1/2
22
mm
521
559
Min. Opening Height
in
18-1/4
17-1/2
mm
464
445
Minimum
Opening
Height
Minimum
Base Dimension
Min. Opening Width
Min. Base Dimension
Minimum
Height above
Bottom of Termination Cap
Chase Top
Radiation Shield
3 in. (76 mm)
Radiation
Shield Height
Termination
Cap
TR342B/344
TR442B/444
or with TR-TVK
Min. Base Dims.
in
27 x 27
mm
686 x 686
Min. Height
Above Bottom of
Termination Cap
in
23
mm
584
Min. Opening Width
in
21
mm
533
Min. Opening Height
in
12
mm
305