15
Outdoor Lifestyles • Villa Gas Owners/Installation Manual • 4072-170 • Rev C • 04/01/14
6
Finishing
A. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or finishing materials must not interfere with
air flow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or finishing materials must never overhang
into the appliance opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the finished wall and appliance top
and sides using a 300º F minimum sealant. Refer to
Figure 10.1.
WARNING! Risk of Fire!
DO NOT
apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specified in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
0 in.
0 in.
0 in.
Finish wall material may be
combustible - Top and Sides
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
12 in. noncombustible
material (required)
Figure 6.1 Non-combustible Facing Diagram