22
Outdoor Lifestyles by Hearth & Home Technologies • Twilight-II-B Installation Manual • 2108-970 Rev. H • 5/14
8
8
Finishing
A. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as speci
fi
ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause
fi
re.
B. Facing Material
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
• Seal joints between
fi
nished wall and appliance top and
sides with 300ºF (140º C) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci
fi
ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
12
11
10
9
8
7
6
13-5/8
12-5/8
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
HOOD
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
CEILING
35-3/4
MEASURED
FROM CORNER
TOP VIEW
FIREPLACE
HOOD
1/2 IN.
Note:
Measurements are in inches.
41-7/8 in.
2-3/4 in.
NON-COMBUSTIBLE ZONE
Figure 8.3 Non-combustible Zone (Interior)
Figure 8.1 Clearances to a Combustible and/or Non-combustible
Indoor Mantel
Figure 8.2 Clearances to a Combustible and/or Non-combustible
Indoor Mantel or Mantel Leg
MINIMUM CLEARANCES
Vinyl
Non-vinyl
A
36 in.
12 in.
B
64-5/16 in.
35-5/16 in.
OVERHANG
A
A
B
SIDING
SIDING
SIDING
FINISHING MATERIALS
A
Finishing Material Clearances
Figure 8.4 Exterior View - Finishing Material Clearances