17
Outdoor Lifestyles by Hearth & Home Technologies • Installation Manual TWILIGHT-II-MOD • 2290-970 Rev. F • 11/13
Electrical Service and Repair
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Figure 6.2 Fan Wiring Diagram
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the appliance is permanently installed. See Figure 6.2.
Fan Installation
Fan should be positioned on the left side (as viewed from
appliance interior side. See Figure 6.3.
NOTE:
For ease
of installation, it is recommended that the fan be installed
prior to gas line installation.
Wall Switch
Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the appliance ON/
OFF switch pigtails.
NOTE: If any of the original wire as supplied
with the appliance must be replaced, it must be
replaced with the type 105
o
C rated wire.
Figure 6.3 Fan location
SEE DETAIL A
WIRE LEAD
2 FEMALE ENDS
PLUG AND WIRE
ASSEMBLY
JUNCTION BOX
6 FT.
APPROX.
TEMPERATURE
SENSOR SWITCH
FAN SPEED
CONTROL
(RHEOSTAT)
DETAIL A
WIRE LEAD
1 MALE END
1 FEMALE END
6 FT.
APPROX.
FAN KIT
#GFK-160T
FAN
DRIP
TRAY
APPLIANCE
LEFT SIDE
APPLIANCE INTERIOR SIDE