31
Outdoor Lifestyles by Hearth & Home Technologies, Inc. • TWILIGHT-II-MOD • 2290-900 Rev. C • 7/12
APPLIANCE
HOOD
TOP OF
APPLIANCE
SOFFIT
SIDING
HOUSEWRAP (BUILDING
PAPER) AND SHEATHING
35-5/16 in.
MINIMUM CLEARANCE
TO NON-VINYL
64-5/16 in.
CLEARANCE TO VINYL
SOFFIT, OVERHANG, MANTEL,
OR CEILING
12 in.
MINIMUM CLEARANCE
TO NON-VINYL SIDING
36 in. MINIMUM
CLEARANCE TO VINYL SIDING
DRAIN PLANE
DETERMINED BY
LOCAL CODE
BRICK OR OTHER NON-COMBUSTIBLE
FACING MATERIAL 6 INCH MAXIMUM
PROJECTION FROM SURFACE OF
FIREPLACE (INCLUDES NON-COMBUSTIBLE
MANTEL PROJECTION)
NON-COMBUSTIBLE BRICK LEDGE
MUST BE TIGHT TO APPLIANCE
FACE OR NON-COMBUSTIBLE SHEATHING
TOP OF HOOD
INSULATION
Figure 10.7 Exterior View with Non-combustible Facing Material
Figure 10.6 Exterior View
DETAIL -
SEE FIGURE 10.5
NOTE:
All fi nishing materials on top of exterior
sheathing must be non-combustible for a minimum
of 10-7/8 inches above and on both sides of
the exterior face of the appliance. This non-
combustible fi nishing material can be up to a
maximum of 6 inches thick (6 inches maximum
horizontal overhang) to allow for brick and stone
alcoves. See Figure 10.7.
NOTE:
Combustible housewrap or building
paper
MUST NOT
extend over the outside of
non-combustible sheathing, and
MAY
extend
over the fl ashing header behind non-combustible
sheathing. Use high temp caulk to seal between
combustible sheathing housewrap and non-
combustible sheathing.
APPLIANCE
HOOD
TOP HOOD
TOP OF
FIREPLACE
10-7/8 in.
CEILING OR OVERHANG
64-5/16 in.
MINIMUM CLEARANCE
TO VINYL SOFFIT,
CEILING OR OVERHANG.
35-5/16 in.
MINIMUM CLEARANCE TO
NON-VINYL SOFFIT, MANTEL,
CEILING OR OVERHANG.
STUD WALL
SOFFIT
HOUSEWRAP
INSULATION
HOUSEWRAP
(BUILDING
PAPER) OVERLAP
FLASHING 1 in.
SHEATHING,
COMBUSTIBLE
FIREPLACE
HEADER
INSULATED
FRAMING
STANDOFF
NON-COMBUSTIBLE
SHEATHING
FLASHING
HEADER