T H E O U T D O O R P L U S . C O M
2 3 5 E A S T M A I N S T
9 0 9 .4 6 0 . 5 5 7 9
P A G E 5
GENERAL INFORMATIONS
Fuel Type
- Before making gas connections ensure appliance being installed is compatible with the available gas
type. Check the label on the appliance to confirm appliance gas type requirement.
Gas Pressure
- Proper input gas pressures are required for optimum appliance performance.
GAS PRESSURE REQUIREMENTS
Natural Gas
Minimum 3.5” W.C. - Nominal: 7.0” W.C. - Maximum 1/2” PSI (14.0” W.C.)
Liquid Propane:
Minimum 8.0” W.C. - Nominal: 11.0” W.C. - Maximum 1/2” PSI (14.0” W.C.)
ELECTRICAL REQUIREMENTS
The All Weather Electronic Ignition System operates on 24 Volts AC power ONLY
DO NOT Attempt to Power using 110 Volts AC Power – Damage WILL RESULT
Acceptable Input Voltages to Supplied 24 Volt AC Transformer: 110 / 210 / 220 / 240 / 480 Volt AC
Supplied 24 Volt AC Transformer compatible with all voltages listed above
Read label on supplied transformer for proper connection information
Recommended Wire Size: 12 gauge wire for all installations
CLEARANCE FROM COMBUSTIBLES
Warning
- Provide adequate clearance
from combustibles as shown below.
INSTALLATION & MAINTENANCE
We suggest that our products be
serviced by a professional certified
in the U.S. By the National Fireplace
Institute as a NFI Specialists
TOP TORCH