Section 2
Important Safety Information
»
The Outdoor Plus Company, Inc./TOPFIRES recommends that our products are
installed by professionals locally licensed by the authority having jurisdiction
in gas piping. All installation instructions must be followed to ensure proper
performance and safety. The Outdoor Plus Company, Inc./TOPFIRES assumes
no responsibility for problems relating to the installation.
»
To qualify for warranty, all instructions must be strictly followed. Otherwise,
warranty may be void. Never alter product or configuration in any way.
»
Annual servicing should be handled by professionals certified in the US by the
National Fireplace Institute (NFI) as NFI Gas Specialists or in Canada by WETT
(Wood Energy Technical Training).
»
It is the installer’s responsibility to ensure a safe installation and to educate
the end-user regarding the features, safety recommendations and proper
operation of this product.
»
Please reference page 1 for all warnings.
IMPORTANT SAFETY INFORMATION FOR INSTALLERS
Leave this manual with the end-user and instruct them to retain it for
future reference. Instructions and product updates are also available at
www.theoutdoorplus.com under the Manuals/Documents tab.
Installers must carefully follow the instructions in this manual to prevent personal injury or property loss.
These instructions contain information critical to the safe installation and operation of the fire pit.
»
Instructions are updated as needed. It is the responsibility of the installers to check for product updates
and installation manual updates at www.theoutdoorplus.com/documents/ prior to installation.
»
It is the responsibility of the installer to follow:
»
The National Fuel Gas Code, ANSIZ223.1/NFPA54 or International Fuel Gas Code.
»
Natural Gas and Propane Installation Code CSA B149.1 or CSA B149.2.
»
The National Electrical Code, ANSI/NFPA70. In Canada, Canadian Electrical Code CSA22.1.
»
Local codes
»
Only use gas/fuel type specified for this fire pit as noted on the fire pit control box label. NEVER use an
alternative fuel to include bio-fuel, ethanol, lighter fluid or any other fuel.
»
Gas pressure and type should be checked prior to installation and use.
»
Natural Gas Fire Pit:
Supply Pressure: Minimum: 6.0 inches W.C.; Maximum: 7.0 inches W.C.
»
LP Gas:
Supply Pressure: Minimum: 8.0 inches W.C.; Maximum: 11.0 inches W.C.
IMPORTANT SAFETY INFORMATION FOR END-USERS
»
Never leave an operating fire pit unattended or with someone not familiar with its operation or emergency
shut-off locations.
»
Both children and adults should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns and clothing ignition.
»
Young children should be carefully supervised when they are in the area of fire pit.
»
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable
vapors and liquids.