1-888-514-1663
| WWW.OUTLANDLIVING.COM
En-5
DISCONNECT
THE IGNITER
CABLE
DISCONNECT
THE
THERMOCOUPLE
GROUND WIRE
DISCONNECT THE
THERMOCOUPLE
CABLE
REMOVE THE
PROPANE HOSE
STEP 4
Remove the (4x) screws holding the gas valve mounting bracket in place.
Remove the gas valve mounting bracket assembly.
SCREW #1
SCREW #2
SCREW #3
SCREW #4
STEP 3
a. Disconnect the igniter cable. Slide protective cap back to expose the cable connection.
Grasp the cable at the base and pull firmly.
b. Disconnect the thermocouple cable. Grasp the cable at the base and pull firmly.
c. Disconnect the thermocouple ground
wire. Remove the screw to release the
wire.
d. Locate the black OUTLAND heat shrink
tubing on the gas hose coupling and
**carefully** remove it using a utility
knife.
e. Remove the propane hose. Uncouple it
from the gas appliance valve assembly
using a wrench (not provided).