OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel. +39 030.3581341
Fax +39 030.3580431
info@outline.it
www.outline.it
10
If any of the parameters have been modified, it is possible to save these changes. If desired, the system will
save the different changes (only in input) for each of the four available presets. To do this, it is enough to select
the “Presets” window and click on the “save” button corresponding to the modified preset. The new settings
will be automatically stored to the DSP memory of the connected SUB 118 SP.
• Sleep Mode
: it is possible to put the enclosure in standby mode, where its power consumption is redu-
ced to 2 Watts, by pushing the “Preset” button for at least 3 seconds. When this mode is on, if after 15
minutes there is no input signal (-45 dBu), the DSP enters the energy saving mode and sends a signal to
the power amplifier that deactivates the output stages. There is a blue LED on the panel indicating the
Sleep Mode is on. The module reactivates when an input signal is present.
In case you wish to restore the default presets, it is possible to download them directly at the following link:
outline.it/download/Settings/SUB118-SP_DefaultPresets.zip
. Once the preset to restore has been chosen, it
will be necessary to import them one by one, by choosing the SUB (right click) from the Armonìa “Workspace”
> “PAM” > “Import...”: