1. Do not light or use gas unit if lava rocks are wet. Ensure lava rocks are completely dry before lighting as intense heat could cause
the lava rocks to crack.
2. Lava rocks could hit somebody' face or eyes during the initial start of this unit, so please keep away from the appliance for the
first 20 minutes.
Regular maintenance of the hose and regulator:
Inspect the hose before each use of the appliance. If the hose shows signs of cracks, abrasions, cuts or damage of any kind, do not
operate the appliance. Fix or replace the hose as required before using the appliance. For assistance with repair o
a)
replacement of the hose, call hero Manufacturing at 1-580-590-7341. Use only replacement parts from the manufacturer
Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when replacing the cylinder or at least once per year. If
there is any indication of damage, have the seal replaced by a certified gas dealer before operating the appliance.
b)
Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service valve.
Hand tighten only.
4.
Be careful to not cross the threads on the connection when tightening the CGA No 791 connection on to the LP gas cylinder service
valve.
5.
“Leak Test” should always be performed after attaching the connection to the LP gas cylinder service valve.
(See “Leak Test” section of this manual)
For the connection of the hose and regulator to the LP tank, refer to the “Connection” section of the LP gas cylinder
section above.
6.
7.
LAVA ROCK USE
WARNING
!
3.
INPUT
30,000 Btu/hr
Propane Regulator
Pressure
Natural Gas Minimum
Inlet Pressure
Clearances to
combustible surfaces
11 inches water column
7 inches water column
Sides: 48in. /121.9 cm
Top: 72 in. / 183 cm
SPECIFICATIONS
Figure 1
CSA (Canadian Standards Association) certified to ANSI Z21.97•CSA 2.41-2017
“Outdoor Decorative Gas Appliances”.