Eureka5 User Manual
CXD-
930
-UM-
044
Version: 1.3
Page
22
of
50
1.
Open the hydrant carefully to ensure there is no debris in the outlet, and clean water flows
(the pressure can be
assessed at this
point).
2.
Ensure the hydrant valve is
shut.
3.
Ensure the seal in the hydrophone is
clean.
4.
Fit the hydrophone to the hydrant and tighten in place. Tightening is best performed by fitting the adaptor
provided onto the castellations on the upper side of the hydrant cap, then using the standard hydrant valve key
to tighten the hydrophone
assembly.
5.
Ensure the bleed valve is closed, and that the fitting is
secure.
6.
Slowly
open the hydrant valve, and check that no leakage occurs from the
hydrophone.
7.
Open the bleed valve
slightly
to allow air to
escape.
8.
Close the bleed valve when only water is
escaping.
When fitted correctly the hydrophone may be connected directly to the transmitter.
Before removing a hydrophone fitting, it is essential to make sure that the hydrant valve is shut.
After closing the Hydrant valve the bleed valve may then be opened to
c
heck that there is no
pressure. Only then should you remove the hydrophone and adapter.
Adhere to local water hygiene regulations when inserting hydrophones into potable water pipes.
4.3
Set-Up Transmitters
1.
Attach antenna.
2.
Position the transmitter as required
.
3.
Switch on the transmitter by holding down the button for 2 seconds.
Summary of Contents for Eureka5
Page 1: ...Version 1 3 Eureka5 User Manual 24 March 2022 CXD 930 UM 044...
Page 6: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 6 of 50 11 Appendix E EU DoC 49...
Page 11: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 11 of 50...
Page 48: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 48 of 50 10 Appendix D UKCA DoC TBA...
Page 49: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 49 of 50 11 Appendix E EU DoC TBA...