Eureka5 User Manual
CXD-
930
-UM-
044
Version: 1.3
Page
33
of
50
5.6.4
Add Pipe Section
To add a pipe section, tap on either of the
A
DD buttons
at the end of the pipe model. A new section will be created with
default length, diameter and material. These can be changed using the actions above. Up to six sections of pipe can make up
the pipe model.
5.6.5
Remove Pipe Section
To remove a section of pipe, tap on the X button toward the top right of the section; this section will then be removed from
the model. A pipe model must consist of at least one section of pipe, so it is not possible to remove the last remaining
section.
5.7
Velocity Correction
Velocity c
orrection overcomes the largest error for accurate leak position.
It allows the true velocity of sound in the pipe(s) to be measured, meaning the accuracy of the distance to the leak can be
improved for multiple materials and/or aging pipes.
There must be a leak in the pipe work at a known location to use this
feature; this is commonly produced by opening a hydrant.
Summary of Contents for Eureka5