background image

5

V1.0

www.ovationlight.com

Installation

Read ‘Safety information’ before installing the fixture.

The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. 
Ensure that none of the fixture’s ventilation slots are blocked.

Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can 
be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, 
secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if 

the primary fastening method fails.

Fastening the fixture to a 

flat

 surface

The fixture can be fastened to a hard, fixed, 

flat

 surface that is oriented at any angle. Ensure that the sur-

face and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be 

installed on it.

Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over. If 
you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed be

-

low with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the 
fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in 

any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.

To clamp the fixture to a truss:

1. 

Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment 

to be installed on it.

2.  Block access under the work area.
3.  Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting 

bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting 

bracket legs and be fastened with a self-locking nut.

4. 

Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp se

-

curely.

5. 

Secure the fixture with a safety cable as directed below.

Summary of Contents for HONOR 250C ZOOM

Page 1: ...USER MANUAL HONOR 250C ZOOM RDM Profile Spot Zoom 250W RGBW...

Page 2: ...g with a safety cable 6 DMX 512 connection connection between fixtures 6 Power connection 7 Operation 7 Control Menu Map 7 Control menu 8 Main Menu 8 Addressing 9 Universal DMX Control 9 RDM control 9...

Page 3: ...the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operatio...

Page 4: ...on Down button Enter button Dmx signal indicator Power indicator Handle Rotary button Dmx out Dmx in Fuse Power out Power in On off switch LCD display Yoke Shutters Gobo holder slot Iris slot Focus kn...

Page 5: ...ved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed be low with a securely anchored safety cable that will hold the fixture...

Page 6: ...rectly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX...

Page 7: ...nternational Brown Live L Blue Neutral N Yellow green Earth Ground Operation The Honor 250C Zoom RDM zoom can operate in three different modes In each mode you can run the fixture as a stand alone fix...

Page 8: ...al Priority DMX Signal priority setting Signal Hold On Off Run if signal cut RDM On Off RDM function on off Screen Timeout 30S Display shut off time Never Screen Brightness 10 100 Display brightness R...

Page 9: ...nly the selected fixture In the case of the Honor 250C Zoom RDM zoom which is 1 2 3 channels fixture If you set for example the address in the 1 channel mode to channel 2 the device will use the chann...

Page 10: ...r function function Dimmer strobe function 1 Press the MENU button to enter the main menu 2 Press the UP or DOWN button to select Mode menu and press ENTER 3 Press DOWN menu and select Manual sub menu...

Page 11: ...enu 4 Select disired dimmer mode Custom dimmer curves 1 Press the MENU button to enter the main menu 2 Press the UP or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mo...

Page 12: ...ontrol CH1 Dimmer 000 255 0 100 dimmer CH2 Strobe 000 004 No function 005 255 Strobe with speed increasing CH3 Red 000 255 Red dimmer 0 100 CH4 Green 000 255 Green dimmer 0 100 CH5 Blue 000 255 Blue d...

Page 13: ...heavy club use we recommend clean ing on a monthly basis Periodic cleaning will ensure longevity and crisp output To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at l...

Page 14: ...240V 50 60Hz Light source 250W LED Color temperature 2800K 8000K LED color RGBW Color Rendition CRI 97 R9 90 TLCI 98 3200K TLCI 96 5600k Zoom scale 18 38 manually 5 10 9 18 lens tube optional Power co...

Page 15: ...15 V1 0 www ovationlight com...

Page 16: ...16 V1 0...

Reviews: