The Oventrop “Regusol” filling and flushing station is used for filling and flushing
solar thermal and heating systems.
It is suitable for water and water-glycol mixtures for solar and heating systems.
With the “Regusol” filling and flushing station, flushing, filling and venting of the
system are safe, quick and clean.
• Suitable solar thermal and heating systems
• Suitable for water and water-glycol mixtures
• Integrated filter at the pump intake
• Easy cleaning and handling
• Robust and durable
• Hose reel and extra large opening
• Pictorial instructions on the station
• Hose connections for Oventrop fittings
Technical data
Dimensions H x W x D 1000 × 400 × 530 mm
Weight (empty)
21 kg
Tank
30 l
Pressure hoses
approx. 2.5 m, with
union nuts ¾"
Drain valve
½''
Max. fluid temperature 65 °C
Fluid
water, water-glycol mixtures for solar thermal systems
Version
DE
US
Article no.
136 42 40
168 42 40
Pump
230 V~ / 50 Hz
115 V~ / 50 - 60 Hz
Connection
Safety connection
US plug type B
Pump pressure
4.2 bar
4.2 bar (60 Hz) / 3,0 bar (50 Hz)
Power consumption
550 W
1000 W
Max. delivery height
42 m
42 m (60 Hz) / 30 m (50 Hz)
Note
Before commissioning the station, please consult the Technical Informa-
tion “Solar thermal systems – Installation, commissioning and mainte-
nance” (see Products / Technical Information on oventrop.de).
1
General information
The “Regusol” filling and flushing station is only suitable for water and water-glycol
mixtures for solar and heating systems. The medium must be free of grit, but may
be polluted. Dirt in the system is held back by the filter situated at the pump intake
inside the tank.
The user must make sure that the “Regusol” filling and flushing station is suitable
for the fluid in use.
WARNING!
Risk of fatal injury by explosion or deflagration!
Using the station with substances having a flashing point lower
than 55 °C can lead to explosions or deflagrations.
Î
Do not use the station with petrol, solvants or other
volatile substances!
ATTENTION!
Pressure surge damage!
If the medium enters strongly heated, empty collectors, pres-
sure surges can occur.
Î
Do not fill or flush the system during times of strong
irradiation!
2
Electrical connection
The cross-section of the connection cable must be at least 1.5 mm².
Note
For your own safety: only use the “Regusol” filling and flushing station in
an electrical circuit fused by a residual current device.