Technical description
“Regumaq X-25”
14
138112581-V01.10.2019
3.5 Technical data
General information
Max. operating pres-
sure (
ps
)
10 bar
Max. operating tem-
perature (
ts
)
95 °C
Ambient temperature
2 – 35 °C
Empty weight
Approx. 13 kg
Connections
Storage cylinder
circuit, potable water
circuit, circulation
G1 male thread high
sealing level
Fill and drain ball
valves
G
3/4
male thread, for
hose connections
Storage cylinder circuit
Fluid
Heating water in accor-
dance with VDI 2035/
ÖNORM H 5195-1; fluid
category ≤ 3 in accor-
dance with EN 1717; see
Oventrop information
sheet on corrosion pro-
tection in the appendix
kv value
2,67 m
3/h
Pump
Wilo Para 15-130/8-75/
UN-9
Power consumption
during operation 2–75 W
Potable water circuit
Fluid
Potable water (see Oven-
trop information sheet on
corrosion protection in
the appendix)
Notice
Damage to measur-
ing turbine caused by
chemical influences!
Water treatment additives
in high concentrations
can damage the measur-
ing turbine.
f
Ensure that the
permitted limits for
potable water are not
exceeded.
Discharge capacity
(where Δ T = 15K)
1–25
l/min
kv value
1.88 m
3/h
Safety valve
10 bar
- General temperature
range:
- Controller presetting:
20 – 75 °C
20 – 60 °C
Material
Valves and fittings
Brass / dezincification-re-
sistant brass
Seals
Fibre material
Insulation
EPP
Pipes
Stainless steel 1.4404
3.4 Example of the application
Design temperatures: 60°C hot water; 75°C flow temperature storage cylinder circuit
(design according to DIN 1988-300)
Number
of “X-45”
stations
Residential
building
Hospital
room
Hotel
room
Communal shower
facility
Buffer
storage
cylinder
volume
[l]
Re-
quired
boiler
capacity
[kW]
1 Washbasin (WB)
1 Kitchen sink (KS)
1 Shower (S)
1 WB
1 S
1 WB
1 S
Number of showers at 6 l/
min 60° PWH
(Simultaneity factor 80 %)
1
3
4
3
5
500
17
2
14
19
12
10
800
33