12
AOM LABEL
INTERFACE CABLE 2
WIRE COLORS
WIRE FUNCTION
UP1 - COM
WHITE/BLUE
OPEN LIMIT COMMON
DN1 - COM
WHITE/BLACK
CLOSE LIMIT COMMON
UP1 - N/O
BLUE/WHITE
OPEN LIMIT
DN1 - N/O
BLACK/WHITE
CLOSE LIMIT
CONNECT INTERFACE TO OPERATOR
NOTE #2:
If the MID-STOP feature on the operator is used, a jumper set must be installed between the MID-STOP
relay on the AOM board to the UP1 N/O and COM contacts.
Fig.4A
Strip wire
Fig.4B
Attach wire
OPERATOR TERMINAL STRIP ID
INTERFACE CABLE 1 WIRE COLORS
WIRE FUNCTION
OPEN
GREEN
OPEN SENSE
CLOSE
BLUE
CLOSE SENSE
STOP
RED
STOP SENSE
GND
WHITE
GROUND
1-BTN
PURPLE
SINGLE ONE BUTTON
ODC-STB
N/A
ODC-STB
ORANGE
MONITORED SAFETY
N/O REVERSE
N/A
N/O REVERSE
YELLOW (*SEE NOTE #1)
N.O. SAFETY
EXT INTLK
N/A
EXT INTLK
BROWN
INTERLOCK
J18 AC POWER CONNECTION
YELLOW
BLACK
24V POWER
BLACK
BLACK
24V POWER
Install #4 forked terminal connectors to each wire and install them per chart below and wire
diagram.
IMPORTANT NOTE:
Cables included with this kit are 4 feet long. If junctions box is more than 3 feet
away from operator, additional wires and connections will be required to lengthen wires.
This junction box must be mounted indoors.
!
#4 Terminal
Connector
J7 EXTERNAL RADIO HARNESS
EXTERNAL RADIO IN
WHITE/RED
N/O RADIO CONTACT (Orange)
EXTERNAL RECEIVER
RELAY OUTPUT
RED/WHITE
RADIO RELAY OUTPUT
MON-EDGE
INTERFACE CABLE 1
YELLOW
MONITORED SAFETY EDGE
NOTE #1:
If using a monitored edge, connect yellow wire to MON EDGE terminal on TCM or ESM.
Connection types: