FOR ASSISTANCE CALL 1-800-275-6187
6.5
NOTE
: The RMX™ Operator can use monitored SERIES II Photocells
(STB). If your application requires these photocells, they must be activat-
ed in calibration mode.
1) Press CAL/RUN to enter calibration mode.
2) Press scroll (DN) until display reads "ODC STB
>
"
3) Press SET/CLEAR) until display reads "ODC STB
>
ON"
• The “STB ENAB” LED on the control board should light.
4) Press CAL/RUN to return to run mode.
NOTES
A)
To turn series II photocells off, repeat process until display reads
"ODC STB
>
OFF."
Fig.
9
.
B)
Installation of Series II monitored photocells (STB) does NOT
make the RMX™ unit legal for residential installation. Overhead
Door does NOT recommend the installation of the RMX™ unit in
residentially zoned construction.
Using Series II Safe-T-Beam
®
(STB)
Monitored Photocells
ODC STB OFF
Figure
9
WARNING:
Photocell systems provide entrapment protection when
mounted near the doorway in such a way that the lower
portion of an individual’s leg will break the photocell beam
during normal walking conditions. If an alternative location is
chosen it must be approved by the facility owner.
07/30/09