78
Chapter 4 - Maintenance
Flash Firmware
Update Status:
Attempting to Sync
With the Host
Figure 4-8
Flash Update Screen
4.
Press <Enter> on the DOS computer. The lower two lines should change to read
Flash Firmware
Update Status:
Programming Sector
XX of 64
Figure 4-9
Flash Update in Process
The fourth line increments until the download is complete, then the following screen appears.
Flash Firmware
Update Status:
Checking CRC
Figure 4-10
Flash Update Check Screen
After completion of the CRC check, the following screen appears.
Flash Firmware
Update Successful
Please Wait While
Library Reboots
Figure 4-11
Flash Update Completion Screen
The Global Control Module now reboots. Do not turn the power off until the Default Screen
appears. You may now disconnect the cable and put the distribution disk away for
safekeeping.
Figure 4-12
Default Screen
Note: You can also perform flash firmware updates from the host through the SCSI bus,
using the Write Firmware command. You will need special software to run on the host for this
purpose. Updating firmware through the SCSI bus uses the same menus as described in the
preceding section.