2-8
u
Installation
C
ONFIGURATION
O
PTIONS
D
ESCRIPTIONS
Set Serial Number
This setting enables you to alter the Base Module’s serial number as stored in the unit. The
Base Module’s robotics reports these settings in response to the SCSI Inquiry command, in the
Unit Serial Number Page.
Set Unload Mode
This setting determines whether a SCSI Move Medium command is interpreted as implicit or
explicit. If implicit, the module unloads a drive before attempting to move a cartridge from that
drive. If explicit, the host must issue a SCSI Unload command to a drive before each Move
Medium command that removes a cartridge from that drive.
Set Autoclean Mode
This setting allows you to enable an automatic cleaning cycle which operates as part of the
cartridge unload sequence whenever the Use Cleaner LED comes on. To use this option, you
must reserve a slot for a cleaning cartridge using the Reserved Slots option.
Set Negotiation
This option offers three choices: Set Negotiation mode, Set Transfer Rate and Set Bus Width.
Negotiation Mode, if set, allows the library to initiate SCSI Synchronous Negotiation with the
host (the default is No). The library always responds to host-initiated negotiation. Set Transfer
Rate can be set to 10 Mbytes/sec, 5 Mbytes/sec or Asynchronous. The default is
10 Mbytes/sec
.
Set Bus Width will display when a controller PWB that does not use Jumper 14 (J14) to set the
SCSI bus width is installed. Select Wide or Narrow to match the SCSI bus of the model you
have.
Set Reserved Slots
Allows user to withdraw a specified number of slots from use in the magazine. Use this option
to meet licensing requirements if necessary and for the cleaning cartridge.
Set Special Configurations
Model number information is displayed on the initial screens. You can choose between
PowerLoader, a blank line, and a vendor unique designator. The default is PowerLoader.
Display of each SCSI elements in the unit to begin with either zero or one. This affects only the
front panel display, not the actual SCSI element addresses.
This option allows you to accommodate different SCSI device implementations. See the Special
Configurations section of
for a list of options and default values.
Set Default
The Default option resets all of the preceding configuration options to factory defaults.