background image

Part Number 10400106-102 04/2008

©2007-2008 Overland Storage, Inc.

Page 1 of 2

This document describes how to remove and replace the 
fan assembly in a REO 9000 or 9100 product from 
Overland Storage.

Unpacking

Carefully unpack and verify that you have all the parts: 

REO 9000/9100

®

 fan assembly in anti-static bag

These remove & replace instructions

WARNING:  To reduce the risk of electric shock or 
damage to equipment, disconnect the power by 
unplugging the power cord.

Electrostatic Discharge Information

A discharge of static electricity can damage micro-circuitry 
or static-sensitive devices. To help prevent electrostatic 
damage, observe the following precautions:

Transport and store items in static-safe containers

Keep electrostatic-sensitive parts in their containers

Use properly-grounded tools

Make sure you are always properly grounded

Keep the work area free of non-conductive materials

Avoid touching pins, leads, or circuitry

Disconnect Power and Connections

1.

Make sure that there are no backup or restore 
operations running on the affected appliance.

2.

In the GUI, click 

Maintenance

 > 

Shut Down

 > 

OK

Wait one minute. Make sure the appliance is shut down 
(all lights are off) before continuing.

3.

Disconnect all data cables from the appliance.

4.

Disconnect the power cords from the appliance.

Remove Appliance from Rack

WARNING:  It is recommended that a mechanical lifter 
(or at least two people) be used to prevent injury during 
rack installation or removal.

1.

Using two people, remove the appliance from the rack 
by extending the slide rails and then releasing the slide 
locks. Place it on an ESD surface.

2.

Remove the screws from the cover of the appliance and 
lift the cover off. Set the screws and cover aside.

Determine Location of the Failed Fan

CAUTION:  

The following steps require enabling power to 

the unit while the cover is off. Overland Storage strongly 
recommends only Authorized Service Providers perform 
these steps.

1.

Reconnect the AC power cords to the unit and to the 
power mains.

2.

Turn the appliance on by holding the power switch in 
the 

power on

 position for approximately 1 second. 

3.

Note which fan is not functioning.
With the power on, check the fans in the rear of the 
appliance. If these fans are working, the failed fan is in 
the center of the appliance. Note the failed fan. 

4.

Power off the appliance (see 

“Disconnect Power and 

Connections,”

 above) and proceed to 

“Remove Fan.”

IMPORTANT:  Identify and note the failed fan 

before

 

powering the appliance off.

 

REO 9000/9100

®

Fan Assembly

Remove & Replace Instructions

Overview & Notes

Small Rear Fan

Large Center Fan

Prepare the Appliance

Replace the Fan