10400455-002
©2008-14 Overland Storage, Inc.
256
SnapScale/RAINcloudOS 4.1 Administrator’s Guide
C - Troubleshooting
Network Reset
NOTE: The reset button is only operational for Uninitialized SnapScale nodes (not part of a cluster).
If an Uninitialized SnapScale node has been configured with incorrect network settings, the
settings can be reset to the default values via the reset button. See
.
The
Reset
button is accessed via a small hole on the side flanges:
•
On the
X2
node, it is just below the Network LED on the Power panel located on the
right flange.
•
On the
X4
, the hole is located just below the Power button on the Power panel located on
the left flange.
Control Panel
Icon & Name
Description
Power
Button
This is the main power button. Turning off system power with this
button removes the main power but keeps standby power supplied
to the system. The power cords should be unplugged before service.
Status
Used as follows:
• Off when the node is off.
• Double flashing
green
when booting.
• Solid
green
during normal operation.
• Flashing
green
when powering down.
• Alternating blink/double blink
green
in maintenance mode.
HDD
Always off.
NIC 1
Indicates network link on the Ethernet 1 port when
green
.
NIC 2
Indicates network link on the Ethernet 2 port when
green
.
Overheat/
Fan Fail
When this LED flashes, it indicates a fan failure. When on
continuously, it indicates an overheat condition.
Power
Supply
Used as follows:
• Solid
green
during normal operation.
• Solid
amber
or off if a module has failed, is not connected, or the
node has been turned off.
i
Reset