Setup
14
313221M
Connect fluid supply hose to outlet hose connections (R,
F
IG
. 6). Fittings are sized to prevent connection errors.
Connect whip hose to fluid supply hose with adapter
(50) and nipple (51). Connect other end of hoses to A
and B inputs of gun.
Connect gun air hose to the gun air input and to the air
filter outlet (Z). If you are using more than one hose bun-
dle, join the air hoses with the nipple (305) provided with
the hose bundle.
On heated units with Fusion guns, connect the supplied
ball valve and quick-disconnect coupler to the gun air
hose, then connect the coupler to the gun air fitting.
For sprayers without a compressor, connect the main air
supply to the quick disconnect fitting on the air filter
behind the front brace. Air supply hose must be at least
5/16 in. (8 mm) ID up to 50 ft (15 m) or 3/8 in. (10 mm)
ID up to 100 ft (30 m).
Turn on air compressor power. Set regulator to desired
output pressure as indicated on the gauge.
The EnergyComplete Sprayer is tested with a plasti-
cizer oil at the factory. Flush out the oil with a compatible
solvent before spraying. See page 23.
4.
Connect Fluid Hoses
5.
Connect Gun Air Hose
6.
Connect main air supply
7.
Turn on Air Compressor
Air Filter/Moisture Separator (Z) is equipped
with an automatic moisture drain.
8.
Flush Before First Use
F
IG
. 6. Hose Connections
R
Z
r_256765_313221_b_4
Summary of Contents for 313221M