background image

General Warranty 

We warrant that the product will be free from defects in materials and workmanship 
for  a  period  of  3  years  (1  year  for  accessories)  from  the  date  of  purchase  of  the 
product by  the original  purchaser  from our  company.  This  warranty only  applies  to 
the original purchaser and is not transferable to a third party.   

If the product proves defective during the warranty period, we will either repair the 
defective product without charge for parts and labour, or will provide a replacement 
in  exchange  for  the  defective  product.  Parts,  modules,  and  replacement  products 
used by our company for warranty work may be new or reconditioned like new. All 
replaced parts, modules and products become the property of our company. 

In  order  to  obtain  service  under  this  warranty,  the  customer  must  notify  our 
company of the defect before the expiration of the warranty period. Customer shall 
be  responsible  for  packaging  and  shipping  the  defective  product  to  the  designated 
service centre, a copy of the customers proof of purchase is also required. 

This  warranty shall  not  apply  to any  defect,  failure  or damage  caused  by improper 
use or improper or inadequate maintenance and care. We shall not be obligated to 
furnish service under this warranty a) to repair damage resulting from attempts by 
personnel  other  than  our  company  representatives  to  install,  repair  or  service  the 
product;  b)  to  repair  damage  resulting  from  improper  use  or  connection  to 
incompatible equipment; c) to repair any damage or malfunction caused by the use 
of not our supplies; or d) to service a product that has been modified or integrated 
with  other  products  when  the  effect  of  such  modification  or  integration  increases 
the time or difficulty of servicing the product.

 

 

Please contact the nearest Sales and Service Offices for services. 

   

Excepting  the  after-sales  services  provided  in  this  summary  or  the  applicable 
warranty statements, we will not offer any guarantee for maintenance declared or 
hinted,  including  but  not  limited  to  the  implied  guarantee  for  marketability  and 
special-purpose  acceptability.  We  should  not  take  any  responsibilities  for  any 
indirect, special, or consequent damages. 

 

Summary of Contents for XDM1041

Page 1: ...ntre a copy of the customers proof of purchase is also required This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care We shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than our company representatives to install repair or service the product b t...

Page 2: ...t Limits 3 Measurement Category 3 2 Quick Start 5 General Inspection 5 Dimensions 5 Foot Stool Adjustment 6 Front Panel Overview 6 Rear Panel Overview 8 User Interface 8 Power On 9 Measurement Connections 10 Data Record Function 12 Manual Record 12 Auto Record 12 3 Troubleshooting 14 4 Appendix 15 Appendix A Enclosure 15 Appendix B General Care and Cleaning 15 Appendix C Line Fuse Replacement 15 ...

Page 3: ...he instrument or other property might occur Safety Symbols Symbols on the Product The following symbol may appear on the product Direct current DC Warning risk of electric shock Alternating current AC Caution risk of danger refer to this manual for specific Warning or Caution information Both direct and alternating current Conforms to European Union directives Ground terminal Chassis Ground IEC Me...

Page 4: ...is product Refer to the user s manual for the Measurement Limits before connecting to the instrument Do not exceed any of the Measurement Limits defined in the following section Do not operate without covers Do not operate the instrument with covers or panels removed Use Proper Fuse Use only the specified type and rating fuse for this instrument Avoid exposed circuit Do not touch exposed junctions...

Page 5: ...his limit can also be expressed as 1000 Vpk maximum Current Input Terminal Measurement Limits The measurement limit from 10A input terminal to COM Input terminal is 10 A DC or AC The measurement limit from μA mA input terminal to COM Input terminal is 600 mA DC or AC Note that the current input terminals will always be at approximately the same voltage as the COM Input terminal Measurement Categor...

Page 6: ...rement CAT III applies to protect against transients in equipment in fixed equipment installations such as distribution panels feeders and short branch circuits and lighting systems in large buildings Measurement CAT IV applies to measurements performed at the source of the low voltage installation Examples are electricity meters and measurements on primary over current protection devices and ripp...

Page 7: ...Manual You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged please get in touch with our distributor responsible for this service or our local offices 3 Check the Complete Instrument If it is found that there is damage to the appearance of the instrument or the instrument cannot work normally or fails i...

Page 8: ... Adjustment Unfold the foot stool on the bottom of the multimeter Front Panel Overview 2 4 5 1 7 3 6 Figure 2 1 Front panel overview Item Name Description 1 LCD Display the user interface 2 Menu selection Keys Activate the corresponding menu ...

Page 9: ...ess or keys to increase or decrease the value 6 Operation Keys Run Stop Start or stop auto trigger When the trigger is stopped the displayed data will be held Record Access menus of manual record and auto record See page 12 Data Record Function Utility Set the auxiliary system function including Language Backlight Clock Default and Serial port Math Perform math operations Max Min dB dBm on the mea...

Page 10: ...ted to the computer via USB Device 2 Line Fuse The fuse rating is 250 V F1AL To replace the fuse see page 15 Appendix C Line Fuse Replacement 3 AC Mains Input AC mains input connector User Interface Trigger Mode Reading Range Function Operation Menus Unit Status Icon Figure 2 3 User interface Single display Trigger Mode Status Icon Display Description Trigger Auto trigger Icon Description Auto rec...

Page 11: ...n Figure 2 4 User interface Dual display Power On 1 Connect the instrument to the AC supply using the supplied power cord Warning To avoid electric shock the instrument must be grounded properly 2 Press down the power button at the front panel the screen shows the boot screen ...

Page 12: ...evice under test to the multimeter according to the method below To avoid instrument damage do not discretionarily switch the measurement function when measuring DC Voltage Measurement DC Voltage AC Voltage Measurement AC Voltage DC Current Measurement DC Current DC Current AC Current Measurement AC Current AC Current ...

Page 13: ...stance Measurement Resistance I Continuity Test Open or Closed Circuit I Diode Measurement I Forward Bias Capacitance Measurement Capacitance Frequency Period Measurement AC Signal Temperature Measurement I Temp Transducer ...

Page 14: ... the data table by serial number The icon will show up on the top of the display Note The measurement function can be switched during manual record Save only the main display readings 2 View the manual record Press the front panel key press the Manual softkey to display the data table Press or keys to turn the page Note When the recording data exceeds the current range the data will be marked as o...

Page 15: ...End softkey to stop recording the data table shows the readings taken Press or keys to turn the page Note Automatic recording function supports switching measurement function In auto range the relay switch may cause jitter the data at this time is invalid It will last about a few hundred milliseconds and the data acquired in this period will be marked as invalid When the dual display is enabled on...

Page 16: ...till exists please contact us for our service 2 The reading does not change when a current signal is input 1 Check whether the test lead is correctly inserted into the current input terminals 2 Check whether the DCI or ACI measurement function is enabled 3 Check whether the DCI measurement function is used to measure AC current If you encounter other problems try to reset the settings or restart t...

Page 17: ... disconnect all test leads before cleaning 2 Clean the outside of the instrument using a wet soft cloth not dripping water Do not make any scuffing when cleaning the LCD screen To avoid damage to the instrument do not use any corrosive chemical cleaning agent Caution To avoid any damage to the instrument do not exposed it to any sprays liquids or solvents Warning Before power on again for operatio...

Page 18: ...correct fuse type Failure to do so could result in personal injury or instrument damage Voltage Fuse 90 240 V AC 250 V F1AL To perform the line fuse replacement follow these steps 1 Turn off the multimeter remove all measurement leads and other cables from the instrument including the power cord 2 Use a flat blade screwdriver to remove the fuse box 3 Replace the fuse with a new one install it into...

Reviews: